ϟ

D. Ferenček

Here are all the papers by D. Ferenček that you can download and read on OA.mg.
D. Ferenček’s last known institution is . Download D. Ferenček PDFs here.

Claim this Profile →
DOI: 10.1140/epjc/s10052-015-3587-2
2015
Cited 112 times
Towards an understanding of the correlations in jet substructure
Over the past decade, a large number of jet substructure observables have been proposed in the literature, and explored at the LHC experiments. Such observables attempt to utilize the internal structure of jets in order to distinguish those initiated by quarks, gluons, or by boosted heavy objects, such as top quarks and W bosons. This report, originating from and motivated by the BOOST2013 workshop, presents original particle-level studies that aim to improve our understanding of the relationships between jet substructure observables, their complementarity, and their dependence on the underlying jet properties, particularly the jet radius and jet transverse momentum. This is explored in the context of quark/gluon discrimination, boosted W boson tagging and boosted top quark tagging.
DOI: 10.1088/1748-0221/16/02/p02027
2021
Cited 34 times
The CMS Phase-1 pixel detector upgrade
The CMS detector at the CERN LHC features a silicon pixel detector as its innermost subdetector. The original CMS pixel detector has been replaced with an upgraded pixel system (CMS Phase-1 pixel detector) in the extended year-end technical stop of the LHC in 2016/2017. The upgraded CMS pixel detector is designed to cope with the higher instantaneous luminosities that have been achieved by the LHC after the upgrades to the accelerator during the first long shutdown in 2013–2014. Compared to the original pixel detector, the upgraded detector has a better tracking performance and lower mass with four barrel layers and three endcap disks on each side to provide hit coverage up to an absolute value of pseudorapidity of 2.5. This paper describes the design and construction of the CMS Phase-1 pixel detector as well as its performance from commissioning to early operation in collision data-taking.
DOI: 10.1016/j.apradiso.2019.108824
2019
Cited 25 times
Dose mapping of the panoramic 60Co gamma irradiation facility at the Ruđer Bošković Institute – Geant4 simulation and measurements
The paper presents the dose mapping of the panoramic 60Co gamma irradiation facility at the Ruđer Bošković Institute in Croatia. Both experimental (using ionisation chamber) and simulation (using the Geant4 Monte Carlo code) studies have been performed and compared. Measured and simulation dose rates are found to be in very good agreement and can be used for the absorbed dose determination in the irradiation chamber in everyday work. In order to get a complete description of the dose distribution in the facility, the transit dose, which has to be taken into consideration at low doses, was also experimentally determined.
DOI: 10.1088/1748-0221/16/12/p12014
2021
Cited 8 times
Comparative evaluation of analogue front-end designs for the CMS Inner Tracker at the High Luminosity LHC
Abstract The CMS Inner Tracker, made of silicon pixel modules, will be entirely replaced prior to the start of the High Luminosity LHC period. One of the crucial components of the new Inner Tracker system is the readout chip, being developed by the RD53 Collaboration, and in particular its analogue front-end, which receives the signal from the sensor and digitizes it. Three different analogue front-ends (Synchronous, Linear, and Differential) were designed and implemented in the RD53A demonstrator chip. A dedicated evaluation program was carried out to select the most suitable design to build a radiation tolerant pixel detector able to sustain high particle rates with high efficiency and a small fraction of spurious pixel hits. The test results showed that all three analogue front-ends presented strong points, but also limitations. The Differential front-end demonstrated very low noise, but the threshold tuning became problematic after irradiation. Moreover, a saturation in the preamplifier feedback loop affected the return of the signal to baseline and thus increased the dead time. The Synchronous front-end showed very good timing performance, but also higher noise. For the Linear front-end all of the parameters were within specification, although this design had the largest time walk. This limitation was addressed and mitigated in an improved design. The analysis of the advantages and disadvantages of the three front-ends in the context of the CMS Inner Tracker operation requirements led to the selection of the improved design Linear front-end for integration in the final CMS readout chip.
DOI: 10.1088/1748-0221/15/03/p03014
2020
Cited 8 times
Beam test performance of prototype silicon detectors for the Outer Tracker for the Phase-2 Upgrade of CMS
A new CMS tracker detector will be installed for operation at the High Luminosity LHC (HL-LHC). This detector comprises modules with two closely spaced parallel sensor plates and front-end ASICs capable of transmitting tracking information to the CMS Level-1 (L1) trigger at the 40 MHz beam crossing rate. The inclusion of tracking information in the L1 trigger decision will be essential for selecting events of interest efficiently at the HL-LHC. The CMS Binary Chip (CBC) has been designed to read out and correlate hits from pairs of tracker sensors, forming so-called track stubs. For the first time, a prototype irradiated module and a full-sized module, both equipped with the version 2 of the CBC, have been operated in test beam facilities. The efficiency of the stub finding logic of the modules for various angles of incidence has been studied. The ability of the modules to reject tracks with transverse momentum less than 2 GeV has been demonstrated. For modules built with irradiated sensors, no significant drop in the stub finding performance has been observed. Results from the beam tests are described in this paper.
DOI: 10.1016/j.nima.2023.168326
2023
Evaluation of HPK <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline" id="d1e1449" altimg="si31.svg"><mml:mrow><mml:msup><mml:mrow><mml:mi>n</mml:mi></mml:mrow><mml:mrow><mml:mo>+</mml:mo></mml:mrow></mml:msup><mml:mtext>-</mml:mtext><mml:mi>p</mml:mi></mml:mrow></mml:math> planar pixel sensors for the CMS Phase-2 upgrade
To cope with the challenging environment of the planned high luminosity upgrade of the Large Hadron Collider (HL-LHC), scheduled to start operation in 2029, CMS will replace its entire tracking system. The requirements for the tracker are largely determined by the long operation time of 10 years with an instantaneous peak luminosity of up to 7.5 × 1034 cm−2 s−1 in the ultimate performance scenario. Depending on the radial distance from the interaction point, the silicon sensors will receive a particle fluence corresponding to a non-ionising energy loss of up to Φeq= 3.5 × 1016 cm−2. This paper focuses on planar pixel sensor design and qualification up to a fluence of Φeq = 1.4 × 1016 cm−2.For the development of appropriate planar pixel sensors an R&D program was initiated, which includes n+-p sensors on 150 mm (6”) wafers with an active thickness of 150 µm with pixel sizes of 100×25 µm2 and 50×50 µm2 manufactured by Hamamatsu Photonics K.K. (HPK). Single chip modules with ROC4Sens and RD53A readout chips were made. Irradiation with protons and neutrons, as well was an extensive test beam campaign at DESY were carried out. This paper presents the investigation of various assemblies mainly with ROC4Sens readout chips. It demonstrates that multiple designs fulfil the requirements in terms of breakdown voltage, leakage current and efficiency. The single point resolution for 50×50 µm2 pixels is measured as 4.0 µm for non-irradiated samples, and 6.3 µm after irradiation to Φeq = 7.2 × 1015 cm−2.
DOI: 10.1088/1748-0221/18/11/p11015
2023
Evaluation of planar silicon pixel sensors with the RD53A readout chip for the Phase-2 Upgrade of the CMS Inner Tracker
Abstract The Large Hadron Collider at CERN will undergo an upgrade in order to increase its luminosity to 7.5 × 10 34 cm -2 s -1 . The increased luminosity during this High-Luminosity running phase, starting around 2029, means a higher rate of proton-proton interactions, hence a larger ionizing dose and particle fluence for the detectors. The current tracking system of the CMS experiment will be fully replaced in order to cope with the new operating conditions. Prototype planar pixel sensors for the CMS Inner Tracker with square 50 μm × 50 μm and rectangular 100 μm × 25 μm pixels read out by the RD53A chip were characterized in the lab and at the DESY-II testbeam facility in order to identify designs that meet the requirements of CMS during the High-Luminosity running phase. A spatial resolution of approximately 3.4 μm (2 μm) is obtained using the modules with 50 μm × 50 μm (100 μm × 25 μm) pixels at the optimal angle of incidence before irradiation. After irradiation to a 1 MeV neutron equivalent fluence of Φ eq = 5.3 × 10 15 cm -2 , a resolution of 9.4 μm is achieved at a bias voltage of 800 V using a module with 50 μm × 50 μm pixel size. All modules retain a hit efficiency in excess of 99% after irradiation to fluences up to 2.1 × 10 16 cm -2 . Further studies of the electrical properties of the modules, especially crosstalk, are also presented in this paper.
DOI: 10.1088/1748-0221/15/04/p04017
2020
Cited 5 times
Experimental study of different silicon sensor options for the upgrade of the CMS Outer Tracker
During the high-luminosity phase of the LHC (HL-LHC), planned to start in 2027, the accelerator is expected to deliver an instantaneous peak luminosity of up to 7.5×1034 cm−2 s−1. A total integrated luminosity of 0300 or even 0400 fb−1 is foreseen to be delivered to the general purpose detectors ATLAS and CMS over a decade, thereby increasing the discovery potential of the LHC experiments significantly. The CMS detector will undergo a major upgrade for the HL-LHC, with entirely new tracking detectors consisting of an Outer Tracker and Inner Tracker. However, the new tracking system will be exposed to a significantly higher radiation than the current tracker, requiring new radiation-hard sensors. CMS initiated an extensive irradiation and measurement campaign starting in 2009 to systematically compare the properties of different silicon materials and design choices for the Outer Tracker sensors. Several test structures and sensors were designed and implemented on 18 different combinations of wafer materials, thicknesses, and production technologies. The devices were electrically characterized before and after irradiation with neutrons, and with protons of different energies, with fluences corresponding to those expected at different radii of the CMS Outer Tracker after 0300 fb−1. The tests performed include studies with β sources, lasers, and beam scans. This paper compares the performance of different options for the HL-LHC silicon sensors with a focus on silicon bulk material and thickness.
DOI: 10.48550/arxiv.1504.00679
2015
Cited 4 times
Towards an Understanding of the Correlations in Jet Substructure
Over the past decade, a large number of jet substructure observables have been proposed in the literature, and explored at the LHC experiments. Such observables attempt to utilize the internal structure of jets in order to distinguish those initiated by quarks, gluons, or by boosted heavy objects, such as top quarks and W bosons. This report, originating from and motivated by the BOOST2013 workshop, presents original particle-level studies that aim to improve our understanding of the relationships between jet substructure observables, their complementarity, and their dependence on the underlying jet properties, particularly the jet radius and jet transverse momentum. This is explored in the context of quark/gluon discrimination, boosted W boson tagging and boosted top quark tagging.
DOI: 10.1088/1748-0221/14/10/p10017
2019
Cited 3 times
The DAQ and control system for the CMS Phase-1 pixel detector upgrade
In 2017 a new pixel detector was installed in the CMS detector. This so-called Phase-1 pixel detector features four barrel layers in the central region and three disks per end in the forward regions. The upgraded pixel detector requires an upgraded data acquisition (DAQ) system to accept a new data format and larger event sizes. A new DAQ and control system has been developed based on a combination of custom and commercial microTCA parts. Custom mezzanine cards on standard carrier cards provide a front-end driver for readout, and two types of front-end controller for configuration and the distribution of clock and trigger signals. Before the installation of the detector the DAQ system underwent a series of integration tests, including readout of the pilot pixel detector, which was constructed with prototype Phase-1 electronics and operated in CMS from 2015 to 2016, quality assurance of the CMS Phase-1 detector during its assembly, and testing with the CMS Central DAQ. This paper describes the Phase-1 pixel DAQ and control system, along with the integration tests and results. A description of the operational experience and performance in data taking is included.
DOI: 10.1088/1748-0221/16/11/p11028
2021
Cited 3 times
Selection of the silicon sensor thickness for the Phase-2 upgrade of the CMS Outer Tracker
Abstract During the operation of the CMS experiment at the High-Luminosity LHC the silicon sensors of the Phase-2 Outer Tracker will be exposed to radiation levels that could potentially deteriorate their performance. Previous studies had determined that planar float zone silicon with n-doped strips on a p-doped substrate was preferred over p-doped strips on an n-doped substrate. The last step in evaluating the optimal design for the mass production of about 200 m 2 of silicon sensors was to compare sensors of baseline thickness (about 300 μm) to thinned sensors (about 240 μm), which promised several benefits at high radiation levels because of the higher electric fields at the same bias voltage. This study provides a direct comparison of these two thicknesses in terms of sensor characteristics as well as charge collection and hit efficiency for fluences up to 1.5 × 10 15 n eq /cm 2 . The measurement results demonstrate that sensors with about 300 μm thickness will ensure excellent tracking performance even at the highest considered fluence levels expected for the Phase-2 Outer Tracker.
DOI: 10.1088/0954-3899/34/7/n01
2007
Cited 3 times
Study of di-boson production with the CMS detector at LHC
The relatively high cross sections and the clean signatures of multi-lepton final states make the and pp → WZ0 → 3ℓ(ℓ = e, μ) processes accessible in early CMS data. The CMS potential for the observation and study of these processes is assessed using fully simulated signal and background Monte Carlo samples. The main systematic effects relevant for cross section measurements with 1 fb−1 and 10 fb−1 of data are addressed. We demonstrate that multiple gauge–boson production in pp collisions at LHC energies can be observed in the early phase of the experiment, with an integrated luminosity of or less.
DOI: 10.1088/1748-0221/18/04/p04001
2023
Test beam performance of a CBC3-based mini-module for the Phase-2 CMS Outer Tracker before and after neutron irradiation
Abstract The Large Hadron Collider (LHC) at CERN will undergo major upgrades to increase the instantaneous luminosity up to 5–7.5×10 34 cm -2 s -1 . This High Luminosity upgrade of the LHC (HL-LHC) will deliver a total of 3000–4000 fb -1 of proton-proton collisions at a center-of-mass energy of 13–14 TeV. To cope with these challenging environmental conditions, the strip tracker of the CMS experiment will be upgraded using modules with two closely-spaced silicon sensors to provide information to include tracking in the Level-1 trigger selection. This paper describes the performance, in a test beam experiment, of the first prototype module based on the final version of the CMS Binary Chip front-end ASIC before and after the module was irradiated with neutrons. Results demonstrate that the prototype module satisfies the requirements, providing efficient tracking information, after being irradiated with a total fluence comparable to the one expected through the lifetime of the experiment.
DOI: 10.1088/1748-0221/17/06/p06039
2022
Beam test performance of a prototype module with Short Strip ASICs for the CMS HL-LHC tracker upgrade
Abstract The Short Strip ASIC (SSA) is one of the four front-end chips designed for the upgrade of the CMS Outer Tracker for the High Luminosity LHC. Together with the Macro-Pixel ASIC (MPA) it will instrument modules containing a strip and a macro-pixel sensor stacked on top of each other. The SSA provides both full readout of the strip hit information when triggered, and, together with the MPA, correlated clusters called stubs from the two sensors for use by the CMS Level-1 (L1) trigger system. Results from the first prototype module consisting of a sensor and two SSA chips are presented. The prototype module has been characterized at the Fermilab Test Beam Facility using a 120 GeV proton beam.
2011
Search for Pair Production of First-Generation Scalar Leptoquarks in pp Collisions at sqrt(s) = 7 TeV
2016
Measurements of the charm jet cross section and nuclear modification factor in pPb collisions at sqrt(s[NN]) = 5.02 TeV
The CMS Collaboration presents the first measurement of the differential cross section of jets from charm quarks produced in proton-lead (pPb) collisions at a nucleon-nucleon center-of-mass energy of sqrt(s[NN]) = 5.02 TeV, as well as results from charm quark jets in proton-proton (pp) collisions at sqrt(s) = 2.76 and 5.02 TeV. By comparing the yields of the pPb and pp collision systems at the same energy, a nuclear modification factor for charm jets from 55 to 400 GeV/c in pPb collisions at sqrt(s[NN]) = 5.02 TeV of R[pA] = 0.92 +/- 0.07 (stat) +/- 0.11 (syst) is obtained. This is consistent with an absence of final-state energy loss for charm quarks in pPb collisions. In addition, the fraction of jets coming from charm quarks is found to be consistent with that predicted by PYTHIA 6 for pp collisions at sqrt(s)= 2.76 and 5.02 TeV, and is independent of the jet transverse momentum from 55 to 400 GeV/c.
2011
Search for Pair Production of First-Generation Scalar Leptoquarks in Proton-Proton Collisions at √s=7 TeV
2011
Search for Pair Production of First-Generation Scalar Leptoquarks in Proton-Proton Collisions at Center of Mass Energy = 7 TeV
2018
Search for the X(5568) State Decaying into B0sπ± in Proton-Proton Collisions at √s=8 TeV
A search for resonance like structures in the B0sπ± invariant mass spectrum is performed using proton-proton collision data collected by the CMS experiment at the LHC at √s=8 TeV, corresponding to an integrated luminosity of 19.7 fb−1. The B0s mesons are reconstructed in the decay chain B0s→J/ψϕ, with J/ψ→μ+μ− and ϕ→K+K−. The B0sπ± invariant mass distribution shows no statistically significant peaks for different selection requirements on the reconstructed B0s and π± candidates. Upper limits are set on the relative production rates of the X(5568) and B0s states times the branching fraction of the decay X(5568)±→B0sπ±. In addition, upper limits are obtained as a function of the mass and the natural width of possible exotic states decaying into B0sπ±.
DOI: 10.22323/1.373.0066
2020
Low dose rate 60Co facility in Zagreb
The Co-60 irradiation facility at Ruđer Bošković Institute in Zagreb allows for gamma irradiation in a large range of doses from a maximum of 30kGy/h down to 30Gy/h. Recently, a setup for the radiation tolerance study of readout electronics has been built inside the irradiation chamber. This setup allows for performing tests in conditions similar to ones that will be experienced at HL-LHC experiments. The irradiation dose rate is close to the dose rate at 3cm from the p-p interaction point, the temperature inside cold boxes is controlled by using chilled water and Peltier elements, and the relative humidity is defined by dry air flushed through the cold boxes. The setup is used for irradiation of ATLAS and CMS pixel detector prototype readout chips, called RD53A. This chip is built in 65 nm CMOS technology that demonstrates a radiation damage dependence on the irradiation dose rate. In this paper the setup itself and a few preliminary results of the radiation damage received at the low dose rate will be presented.
DOI: 10.7566/jpscp.34.010023
2021
Production, Calibration, and Performance of the Layer 1 Replacement Modules for the CMS Pixel Detector