Evaluating Variability in Tumor Measurements from Same-day Repeat CT Scans of Patients with Non–Small Cell Lung Cancer

Binsheng Zhao,Leonard P. James,Chaya S. Moskowitz,Pengcheng Guo,Michelle S. Ginsberg,Robert A. Lefkowitz,Yong Qin,Gregory J. Riely,Mark G. Kris,Lawrence H. Schwartz

Medicine
Lung cancer
Radiology
2009
Purpose To evaluate the variability of tumor unidimensional, bidimensional, and volumetric measurements on same-day repeat computed tomographic (CT) scans in patients with non–small cell lung cancer. Materials and Methods This HIPAA–compliant study was approved by the institutional review board, with informed patient consent. Thirty-two patients with non–small cell lung cancer, each of whom underwent two CT scans of the chest within 15 minutes by using the same imaging protocol, were included in this study. Three radiologists independently measured the two greatest diameters of each lesion on both scans and, during another session, measured the same tumors on the first scan. In a separate analysis, computer software was applied to assist in the calculation of the two greatest diameters and the volume of each lesion on both scans. Concordance correlation coefficients (CCCs) and Bland-Altman plots were used to assess the agreements between the measurements of the two repeat scans (reproducibility) and between the two repeat readings of the same scan (repeatability). Results The reproducibility and repeatability of the three radiologists' measurements were high (all CCCs, ≥0.96). The reproducibility of the computer-aided measurements was even higher (all CCCs, 1.00). The 95% limits of agreements for the computer-aided unidimensional, bidimensional, and volumetric measurements on two repeat scans were (−7.3%, 6.2%), (−17.6%, 19.8%), and (−12.1%, 13.4%), respectively. Conclusion Chest CT scans are well reproducible. Changes in unidimensional lesion size of 8% or greater exceed the measurement variability of the computer method and can be considered significant when estimating the outcome of therapy in a patient. © RSNA, 2009
Loading...
    Cite this:
Generate Citation
Powered by Citationsy*
    Evaluating Variability in Tumor Measurements from Same-day Repeat CT Scans of Patients with Non–Small Cell Lung Cancer” is a paper by Binsheng Zhao Leonard P. James Chaya S. Moskowitz Pengcheng Guo Michelle S. Ginsberg Robert A. Lefkowitz Yong Qin Gregory J. Riely Mark G. Kris Lawrence H. Schwartz published in 2009. It has an Open Access status of “green”. You can read and download a PDF Full Text of this paper here.