ϟ

Tommaso Isidori

Here are all the papers by Tommaso Isidori that you can download and read on OA.mg.
Tommaso Isidori’s last known institution is . Download Tommaso Isidori PDFs here.

Claim this Profile →
DOI: 10.1140/epjc/s10052-019-6567-0
2019
Cited 88 times
First measurement of elastic, inelastic and total cross-section at $$\sqrt{s}=13$$ s = 13 TeV by TOTEM and overview of cross-section data at LHC energies
The TOTEM collaboration has measured the proton–proton total cross section at $$\sqrt{s}=13~\hbox {TeV}$$ with a luminosity-independent method. Using dedicated $$\beta ^{*}=90~\hbox {m}$$ beam optics, the Roman Pots were inserted very close to the beam. The inelastic scattering rate has been measured by the T1 and T2 telescopes during the same LHC fill. After applying the optical theorem the total proton–proton cross section is $$\sigma _\mathrm{tot}=(110.6~\pm ~3.4$$ ) mb, well in agreement with the extrapolation from lower energies. This method also allows one to derive the luminosity-independent elastic and inelastic cross sections: $$\sigma _\mathrm{el}=(31.0~\pm ~1.7)~\hbox {mb}$$ and $$\sigma _\mathrm{inel}=(79.5~\pm ~1.8)~\hbox {mb}$$ .
DOI: 10.1140/epjc/s10052-019-7223-4
2019
Cited 82 times
First determination of the $${\rho }$$ parameter at $${\sqrt{s} = 13}$$ TeV: probing the existence of a colourless C-odd three-gluon compound state
Abstract The TOTEM experiment at the LHC has performed the first measurement at $$\sqrt{s} = 13\,\mathrm{TeV}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:msqrt><mml:mi>s</mml:mi></mml:msqrt><mml:mo>=</mml:mo><mml:mn>13</mml:mn><mml:mspace /><mml:mi>TeV</mml:mi></mml:mrow></mml:math> of the $$\rho $$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mi>ρ</mml:mi></mml:math> parameter, the real to imaginary ratio of the nuclear elastic scattering amplitude at $$t=0$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mi>t</mml:mi><mml:mo>=</mml:mo><mml:mn>0</mml:mn></mml:mrow></mml:math> , obtaining the following results: $$\rho = 0.09 \pm 0.01$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mi>ρ</mml:mi><mml:mo>=</mml:mo><mml:mn>0.09</mml:mn><mml:mo>±</mml:mo><mml:mn>0.01</mml:mn></mml:mrow></mml:math> and $$\rho = 0.10 \pm 0.01$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mi>ρ</mml:mi><mml:mo>=</mml:mo><mml:mn>0.10</mml:mn><mml:mo>±</mml:mo><mml:mn>0.01</mml:mn></mml:mrow></mml:math> , depending on different physics assumptions and mathematical modelling. The unprecedented precision of the $$\rho $$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mi>ρ</mml:mi></mml:math> measurement, combined with the TOTEM total cross-section measurements in an energy range larger than $$10\,\mathrm{TeV}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mn>10</mml:mn><mml:mspace /><mml:mi>TeV</mml:mi></mml:mrow></mml:math> (from 2.76 to $$13\,\mathrm{TeV}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mn>13</mml:mn><mml:mspace /><mml:mi>TeV</mml:mi></mml:mrow></mml:math> ), has implied the exclusion of all the models classified and published by COMPETE. The $$\rho $$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mi>ρ</mml:mi></mml:math> results obtained by TOTEM are compatible with the predictions, from other theoretical models both in the Regge-like framework and in the QCD framework, of a crossing-odd colourless 3-gluon compound state exchange in the t -channel of the proton–proton elastic scattering. On the contrary, if shown that the crossing-odd 3-gluon compound state t -channel exchange is not of importance for the description of elastic scattering, the $$\rho $$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mi>ρ</mml:mi></mml:math> value determined by TOTEM would represent a first evidence of a slowing down of the total cross-section growth at higher energies. The very low-| t | reach allowed also to determine the absolute normalisation using the Coulomb amplitude for the first time at the LHC and obtain a new total proton–proton cross-section measurement $$\sigma _{\mathrm{tot}} = (110.3 \pm 3.5)\,\mathrm{mb}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:msub><mml:mi>σ</mml:mi><mml:mi>tot</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mrow><mml:mo>(</mml:mo><mml:mn>110.3</mml:mn><mml:mo>±</mml:mo><mml:mn>3.5</mml:mn><mml:mo>)</mml:mo></mml:mrow><mml:mspace /><mml:mi>mb</mml:mi></mml:mrow></mml:math> , completely independent from the previous TOTEM determination. Combining the two TOTEM results yields $$\sigma _{\mathrm{tot}} = (110.5 \pm 2.4)\,\mathrm{mb}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:msub><mml:mi>σ</mml:mi><mml:mi>tot</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mrow><mml:mo>(</mml:mo><mml:mn>110.5</mml:mn><mml:mo>±</mml:mo><mml:mn>2.4</mml:mn><mml:mo>)</mml:mo></mml:mrow><mml:mspace /><mml:mi>mb</mml:mi></mml:mrow></mml:math> .
2024
Beam test of n-type Silicon pad array detector at PS CERN
This work reports the testing of a Forward Calorimeter (FoCal) prototype based on an n-type Si pad array detector at the CERN PS accelerator. The FoCal is a proposed upgrade in the ALICE detector operating within the pseudorapidity range of 3.2 < $\mathrm{\eta}$ < 5.8. It aims to measure direct photons, neutral hadrons, vector mesons, and jets for the study of gluon saturation effects in the unexplored region of low momentum fraction x ($\mathrm{\sim10^{-5} - 10^{-6}}$). The prototype is a $\mathrm{8\times9}$ n-type Si pad array detector with each pad occupying one cm$^2$ area, fabricated on a 6-in, 325~$\mathrm{\pm 10 \thinspace \mu}$m thick, and high-resistivity ($\sim$7 k$\Omega \thinspace$ cm) Si wafer which is readout using HGCROCv2 chip. The detector is tested using pion beams of energy 10~GeV and electron beams of energy 1-5~GeV. The measurements of the Minimum Ionizing Particle (MIP) response of pions and the shower profiles of electrons are reported.
DOI: 10.48550/arxiv.2403.14577
2024
Application of the VMM ASIC for SiPM-based calorimetry
Highly integrated multichannel readout electronics is crucial in contemporary particle physics experiments. A novel silicon photomultiplier readout system based on the VMM3a ASIC was developed, for the first time exploiting this chip for calorimetric purposes. To extend the dynamic range the signal from each SiPM channel was processed by two electronics channels with different gain. A fully operational prototype system with 256 SiPM readout channels allowed the collection of data from a prototype of the ALICE Forward Hadron Calorimeter (FoCal-H). The design and the test beam results using high energy hadron beams are presented and discussed, confirming the applicability of VMM3a-based solutions for energy measurements in a high rate environment.
DOI: 10.1140/epjc/s10052-022-10065-x
2022
Cited 6 times
Characterisation of the dip-bump structure observed in proton–proton elastic scattering at $$\sqrt{s}$$ = 8 TeV
Abstract The TOTEM collaboration at the CERN LHC has measured the differential cross-section of elastic proton–proton scattering at $$\sqrt{s} = 8\,\mathrm{TeV}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:msqrt> <mml:mi>s</mml:mi> </mml:msqrt> <mml:mo>=</mml:mo> <mml:mn>8</mml:mn> <mml:mspace /> <mml:mi>TeV</mml:mi> </mml:mrow> </mml:math> in the squared four-momentum transfer range $$0.2\,\mathrm{GeV^{2}}&lt; |t| &lt; 1.9\,\mathrm{GeV^{2}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>0.2</mml:mn> <mml:mspace /> <mml:msup> <mml:mi>GeV</mml:mi> <mml:mn>2</mml:mn> </mml:msup> <mml:mo>&lt;</mml:mo> <mml:mrow> <mml:mo>|</mml:mo> <mml:mi>t</mml:mi> <mml:mo>|</mml:mo> </mml:mrow> <mml:mo>&lt;</mml:mo> <mml:mn>1.9</mml:mn> <mml:mspace /> <mml:msup> <mml:mi>GeV</mml:mi> <mml:mn>2</mml:mn> </mml:msup> </mml:mrow> </mml:math> . This interval includes the structure with a diffractive minimum (“dip”) and a secondary maximum (“bump”) that has also been observed at all other LHC energies, where measurements were made. A detailed characterisation of this structure for $$\sqrt{s} = 8\,\mathrm{TeV}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:msqrt> <mml:mi>s</mml:mi> </mml:msqrt> <mml:mo>=</mml:mo> <mml:mn>8</mml:mn> <mml:mspace /> <mml:mi>TeV</mml:mi> </mml:mrow> </mml:math> yields the positions, $$|t|_{\mathrm{dip}} = (0.521 \pm 0.007)\,\mathrm{GeV^2}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:msub> <mml:mrow> <mml:mo>|</mml:mo> <mml:mi>t</mml:mi> <mml:mo>|</mml:mo> </mml:mrow> <mml:mi>dip</mml:mi> </mml:msub> <mml:mo>=</mml:mo> <mml:mrow> <mml:mo>(</mml:mo> <mml:mn>0.521</mml:mn> <mml:mo>±</mml:mo> <mml:mn>0.007</mml:mn> <mml:mo>)</mml:mo> </mml:mrow> <mml:mspace /> <mml:msup> <mml:mi>GeV</mml:mi> <mml:mn>2</mml:mn> </mml:msup> </mml:mrow> </mml:math> and $$|t|_{\mathrm{bump}} = (0.695 \pm 0.026)\,\mathrm{GeV^2}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:msub> <mml:mrow> <mml:mo>|</mml:mo> <mml:mi>t</mml:mi> <mml:mo>|</mml:mo> </mml:mrow> <mml:mi>bump</mml:mi> </mml:msub> <mml:mo>=</mml:mo> <mml:mrow> <mml:mo>(</mml:mo> <mml:mn>0.695</mml:mn> <mml:mo>±</mml:mo> <mml:mn>0.026</mml:mn> <mml:mo>)</mml:mo> </mml:mrow> <mml:mspace /> <mml:msup> <mml:mi>GeV</mml:mi> <mml:mn>2</mml:mn> </mml:msup> </mml:mrow> </mml:math> , as well as the cross-section values, $$\left. {\mathrm{d}\sigma /\mathrm{d}t}\right| _{\mathrm{dip}} = (15.1 \pm 2.5)\,\mathrm{{\mu b/GeV^2}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:msub> <mml:mfenced> <mml:mrow> <mml:mi>d</mml:mi> <mml:mi>σ</mml:mi> <mml:mo>/</mml:mo> <mml:mi>d</mml:mi> <mml:mi>t</mml:mi> </mml:mrow> </mml:mfenced> <mml:mi>dip</mml:mi> </mml:msub> <mml:mo>=</mml:mo> <mml:mrow> <mml:mo>(</mml:mo> <mml:mn>15.1</mml:mn> <mml:mo>±</mml:mo> <mml:mn>2.5</mml:mn> <mml:mo>)</mml:mo> </mml:mrow> <mml:mspace /> <mml:mrow> <mml:mi>μ</mml:mi> <mml:mi>b</mml:mi> <mml:mo>/</mml:mo> <mml:msup> <mml:mi>GeV</mml:mi> <mml:mn>2</mml:mn> </mml:msup> </mml:mrow> </mml:mrow> </mml:math> and $$\left. {\mathrm{d}\sigma /\mathrm{d}t}\right| _{\mathrm{bump}} = (29.7 \pm 1.8)\,\mathrm{{\mu b/GeV^2}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:msub> <mml:mfenced> <mml:mrow> <mml:mi>d</mml:mi> <mml:mi>σ</mml:mi> <mml:mo>/</mml:mo> <mml:mi>d</mml:mi> <mml:mi>t</mml:mi> </mml:mrow> </mml:mfenced> <mml:mi>bump</mml:mi> </mml:msub> <mml:mo>=</mml:mo> <mml:mrow> <mml:mo>(</mml:mo> <mml:mn>29.7</mml:mn> <mml:mo>±</mml:mo> <mml:mn>1.8</mml:mn> <mml:mo>)</mml:mo> </mml:mrow> <mml:mspace /> <mml:mrow> <mml:mi>μ</mml:mi> <mml:mi>b</mml:mi> <mml:mo>/</mml:mo> <mml:msup> <mml:mi>GeV</mml:mi> <mml:mn>2</mml:mn> </mml:msup> </mml:mrow> </mml:mrow> </mml:math> , for the dip and the bump, respectively.
DOI: 10.1088/1748-0221/12/03/p03024
2017
Cited 11 times
Test of Ultra Fast Silicon Detectors for the TOTEM upgrade project
This paper describes the performance of a prototype timing detector, based on 50 μm thick Ultra Fast Silicon Detector, as measured in a beam test using a 180 GeV/c momentum pion beam. The dependence of the time precision on the pixel capacitance and bias voltage is investigated in this paper. A timing precision from 30 ps to 100 ps (RMS), depending on the pixel capacitance, has been measured at a bias voltage of 180 V.
DOI: 10.3390/instruments7020014
2023
Fast Timing Detectors and Applications in Cosmic Ray Physics and Medical Science
We use fast silicon detectors and the fast sampling method originally developed for high energy physics for two applications: cosmic ray measurements in collaboration with NASA and dose measurements during flash beam cancer treatment. The cosmic ray measurement will benefit from the fast sampling method to measure the Bragg peak where the particle stops in the silicon detector and the dose measurement is performed by counting the number of particles that enter the detector.
DOI: 10.1088/1361-6560/ac0587
2021
Cited 6 times
Performance of a low gain avalanche detector in a medical linac and characterisation of the beam profile
Low gain avalanche detectors can measure charged particle fluences with high speed and spatial precision, and are a promising technology for radiation monitoring and dosimetry. A detector has been tested in a medical linac where single particles were observed with a time resolution of 50\,ps. The integrated response is similar to a standard ionising chamber but with a spatial precision twenty times finer, and a temporal precision over 100 million times better, with the capability to measure the charge deposited by a single linac pulse. The unprecedented resolving power allows the structure of the $\sim 3\,\mu$s linac pulses to be viewed and the 350\,ps sub-pulses in the train to be observed.
DOI: 10.48550/arxiv.1712.06153
2017
Cited 6 times
First measurement of elastic, inelastic and total cross-section at $\sqrt{s}=13$ TeV by TOTEM and overview of cross-section data at LHC energies
The TOTEM collaboration has measured the proton-proton total cross section at $\sqrt{s}=13$ TeV with a luminosity-independent method. Using dedicated $β^{*}=90$ m beam optics, the Roman Pots were inserted very close to the beam. The inelastic scattering rate has been measured by the T1 and T2 telescopes during the same LHC fill. After applying the optical theorem the total proton-proton cross section is $σ_{\rm tot}=(110.6 \pm 3.4$) mb, well in agreement with the extrapolation from lower energies. This method also allows one to derive the luminosity-independent elastic and inelastic cross sections: $σ_{\rm el} = (31.0 \pm 1.7)$ mb and $σ_{\rm inel} = (79.5 \pm 1.8)$ mb.
DOI: 10.1016/j.nima.2021.165599
2021
Cited 5 times
A novel technique for real-time ion identification and energy measurement for in situ space instrumentation
The AGILE (Advanced enerGetic Ion eLectron tElescope) project focuses on the development of a compact low-cost space-based instrument to measure the intensities of charged particles and ions in space. Using multiple layers of fast silicon sensors and custom front-end electronics, the instrument is designed for real-time particle identification of a large variety of elements from H to Fe and spanning energies from 1 to 100 MeV per nucleon. The robust method proposed in this work uses key defining features of electronic signals generated by charged particles (ions) traveling through silicon layers to reliably identify and characterize particles in situ. AGILE will use this real-time pulse shape discrimination technique for the first time in space based instrumentation.
DOI: 10.1088/1748-0221/12/03/p03026
2017
Cited 5 times
Timing performance of a double layer diamond detector
In order to improve the time precision of detectors based on diamonds sensors we have built a detector with two scCVD layers connected in parallel to the same amplifier. This work describes the design and the first measurements of such a prototype performed on a particle beam at CERN. With this different configuration we have obtained an improvement larger than a factor of 1.6–1.7 for the timing precision of the measurement when compared to a one layer scCVD diamond detector.
2018
Cited 5 times
First determination of the $\rho $ parameter at $\sqrt{s} = 13$ TeV -- probing the existence of a colourless three-gluon bound state
The TOTEM experiment at the LHC has performed the first measurement at $\sqrt{s} = 13$ TeV of the $\rho$ parameter, the real to imaginary ratio of the nuclear elastic scattering amplitude at $t=0$, obtaining the following results: $\rho = 0.09 \pm 0.01$ and $\rho = 0.10 \pm 0.01$, depending on different physics assumptions and mathematical modelling. The unprecedented precision of the $\rho$ measurement, combined with the TOTEM total cross-section measurements in an energy range larger than 10 TeV (from 2.76 to 13 TeV), has implied the exclusion of all the models classified and published by COMPETE. The $\rho$ results obtained by TOTEM are compatible with the predictions, from alternative theoretical models both in the Regge-like framework and in the QCD framework, of a colourless 3-gluon bound state exchange in the $t$-channel of the proton-proton elastic scattering. On the contrary, if shown that the 3-gluon bound state $t$-channel exchange is not of importance for the description of elastic scattering, the $\rho$ value determined by TOTEM would represent a first evidence of a slowing down of the total cross-section growth at higher energies. The very low-$|t|$ reach allowed also to determine the absolute normalisation using the Coulomb amplitude for the first time at the LHC and obtain a new total proton-proton cross-section measurement $\sigma_{tot} = 110.3 \pm 3.5$ mb, completely independent from the previous TOTEM determination. Combining the two TOTEM results yields $\sigma_{tot} = 110.5 \pm 2.4$ mb.
DOI: 10.1088/1748-0221/16/07/p07023
2021
Cited 4 times
Test beam characterization of sensor prototypes for the CMS Barrel MIP Timing Detector
The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of the detector, the Barrel Timing Layer (BTL), will be instrumented with LYSO:Ce crystals and Silicon Photomultipliers (SiPMs) providing a time resolution of about 30 ps at the beginning of operation, and degrading to 50-60 ps at the end of the detector lifetime as a result of radiation damage. In this work, we present the results obtained using a 120 GeV proton beam at the Fermilab Test Beam Facility to measure the time resolution of unirradiated sensors. A proof-of-concept of the sensor layout proposed for the barrel region of the MTD, consisting of elongated crystal bars with dimensions of about 3 x 3 x 57 mm$^3$ and with double-ended SiPM readout, is demonstrated. This design provides a robust time measurement independent of the impact point of the MIP along the crystal bar. We tested LYSO:Ce bars of different thickness (2, 3, 4 mm) with a geometry close to the reference design and coupled to SiPMs manufactured by Hamamatsu and Fondazione Bruno Kessler. The various aspects influencing the timing performance such as the crystal thickness, properties of the SiPMs (e.g. photon detection efficiency), and impact angle of the MIP are studied. A time resolution of about 28 ps is measured for MIPs crossing a 3 mm thick crystal bar, corresponding to an MPV energy deposition of 2.6 MeV, and of 22 ps for the 4.2 MeV MPV energy deposition expected in the BTL, matching the detector performance target for unirradiated devices.
DOI: 10.17161/merrill.2019.13337
2019
Cross-Disciplinary Research: From Nuclear Physics to Cosmic Ray Detection and Medical Applications
After a short introduction about the Large Hadron Collider at CERN, Switzerland, we will discuss briefly the fast timing detectors built to measure intact protons.The applications of these detectors concerning cosmic-ray detection and medical applications will be described.
DOI: 10.48550/arxiv.1702.05180
2017
Test of UFSD Silicon Detectors for the TOTEM Upgrade Project
This paper describes the performance of a prototype timing detector, based on 50 micrometer thick Ultra Fast Silicon Detector, as measured in a beam test using a 180 GeV/c momentum pion beam. The dependence of the time precision on the pixel capacitance and the bias voltage is investigated here. A timing precision from 30 ps to 100 ps, depending on the pixel capacitance, has been measured at a bias voltage of 180 V. Timing precision has also been measured as a function of the bias voltage.
DOI: 10.1109/tns.2022.3159660
2022
AGILE Instrument: Advanced Energetic Ion Electron Telescope
Identifying charged particles using crucial features of the reconstructed waveforms is a widely exploited strategy for signal analysis in the class of pulse shape discrimination (PSD) techniques. This document details the design, development, and characterization of the hardware of a compact and low-power consumption telescope for data collection in space. The advanced energetic ion electron telescope (AGILE) experimental apparatus includes a stack of three 20-mm-diameter circular Si detector layers read-out by custom-made double-gain electronics that is optimized for the wide spectrum of expected energy depositions (1&#x2013;100 MeV/nucleon). At the end of its front-end chain, the instrument uses a fast digitizing and sampler device based on commercial components, integrated in a control board developed by the collaboration. In this report, we motivate AGILE&#x2019;s hardware design and report the results obtained during the instrument&#x2019;s prototype laboratory test characterization.
DOI: 10.48550/arxiv.1812.04732
2018
First determination of the $ρ$ parameter at $\sqrt{s} = 13$ TeV -- probing the existence of a colourless three-gluon bound state
The TOTEM experiment at the LHC has performed the first measurement at $\sqrt{s} = 13$ TeV of the $ρ$ parameter, the real to imaginary ratio of the nuclear elastic scattering amplitude at $t=0$, obtaining the following results: $ρ= 0.09 \pm 0.01$ and $ρ= 0.10 \pm 0.01$, depending on different physics assumptions and mathematical modelling. The unprecedented precision of the $ρ$ measurement, combined with the TOTEM total cross-section measurements in an energy range larger than 10 TeV (from 2.76 to 13 TeV), has implied the exclusion of all the models classified and published by COMPETE. The $ρ$ results obtained by TOTEM are compatible with the predictions, from alternative theoretical models both in the Regge-like framework and in the QCD framework, of a colourless 3-gluon bound state exchange in the $t$-channel of the proton-proton elastic scattering. On the contrary, if shown that the 3-gluon bound state $t$-channel exchange is not of importance for the description of elastic scattering, the $ρ$ value determined by TOTEM would represent a first evidence of a slowing down of the total cross-section growth at higher energies. The very low-$|t|$ reach allowed also to determine the absolute normalisation using the Coulomb amplitude for the first time at the LHC and obtain a new total proton-proton cross-section measurement $σ_{tot} = 110.3 \pm 3.5$ mb, completely independent from the previous TOTEM determination. Combining the two TOTEM results yields $σ_{tot} = 110.5 \pm 2.4$ mb.
2021
arXiv : Production of light (anti)nuclei in pp collisions at $\sqrt{s}~=~5.02$ TeV
2021
Observation of a multiplicity dependence in the $p_{\rm T}$-differential charm baryon-to-meson ratios in proton-proton collisions at $\sqrt{s} = 13$ TeV
DOI: 10.1002/essoar.10509035.1
2021
AGILE: An innovative instrument concept to identify and characterize solar energetic particles
Earth and Space Science Open Archive This preprint has been submitted to and is under consideration at Journal of Geophysical Research - Space Physics. ESSOAr is a venue for early communication or feedback before peer review. Data may be preliminary.Learn more about preprints preprintOpen AccessYou are viewing the latest version by default [v1]AGILE: An innovative instrument concept to identify and characterize solar energetic particlesAuthorsShrikanth GKanekaliDChristopheRoyonDoumergW. d'AssigniesFlorianGautieriDAshley DGreeleyiDTommasoIsidoriNicolaMinafraiDAlexanderNovikoviDEricOberlaQuintinSchillerRobertYoungSee all authors Shrikanth G KanekaliDCorresponding Author• Submitting AuthorNational Aeronautics and Space Administration (NASA)iDhttps://orcid.org/0000-0001-8157-4281view email addressThe email was not providedcopy email addressChristophe RoyonDepartment of Physics and Astronomy, University of Kansasview email addressThe email was not providedcopy email addressDoumerg W. d'AssigniesDepartment of Physics and Astronomy, University of Kansasview email addressThe email was not providedcopy email addressFlorian GautieriDDepartment of Physics and Astronomy, University of KansasiDhttps://orcid.org/0000-0001-8790-4499view email addressThe email was not providedcopy email addressAshley D GreeleyiDNASA Goddard Space Flight CenteriDhttps://orcid.org/0000-0002-7394-3638view email addressThe email was not providedcopy email addressTommaso IsidoriDepartment of Physics and Astronomy, University of Kansasview email addressThe email was not providedcopy email addressNicola MinafraiDDepartment of Physics and Astronomy, University of KansasiDhttps://orcid.org/0000-0003-4002-1888view email addressThe email was not providedcopy email addressAlexander NovikoviDDepartment of Physics and Astronomy, University of KansasiDhttps://orcid.org/0000-0002-1086-7252view email addressThe email was not providedcopy email addressEric OberlaKavli Institute for Cosmological Physicsview email addressThe email was not providedcopy email addressQuintin SchillerNASA, Goddard Space Flight Centerview email addressThe email was not providedcopy email addressRobert Young3Instrumentation Design Laboratory, University of Kansasview email addressThe email was not providedcopy email address