ϟ

N. Pastika

Here are all the papers by N. Pastika that you can download and read on OA.mg.
N. Pastika’s last known institution is . Download N. Pastika PDFs here.

Claim this Profile →
DOI: 10.1088/1748-0221/11/03/c03020
2016
Cited 5 times
Performance of the prototype readout system for the CMS endcap hadron calorimeter upgrade
The CMS experiment at the CERN Large Hadron Collider (LHC) will upgrade the photon detection and readout systems of its barrel and endcap hadron calorimeters (HCAL) through the second long shutdown of the LHC in 2018. The upgrade includes new silicon photomultipliers (SiPMs), SiPM control electronics, signal digitization via the Fermilab QIE11 ASIC, data formatting and serialization via a Microsemi FPGA, and data transmission via CERN Versatile Link technology. The first prototype system for the endcap HCAL has been assembled and characterized on the bench and in a test beam. The design of this new system and prototype performance are described.
DOI: 10.48550/arxiv.2312.13405
2023
First Detection of 120 GeV Protons with Superconducting Nanowire Detectors
We report the test results for a 120 GeV proton beam incident on superconducting nanowire particle detectors of various wire sizes. NbN devices with the same sensitive area were fabricated with different wire widths and tested at a temperature of 2.8 K. The relative detection efficiency was extracted from bias current scans for each device. The results show that the wire width is a critical factor in determining the detection efficiency and larger wire widths than 400 nm leads to inefficiencies at low bias currents. These results are particularly relevant for novel applications at accelerator facilities, such as the Electron-Ion Collider, where cryogenic cooling is readily available.
2014
Search for a heavy right-handed W Boson and heavy neutrino of the left-right symmetric standard model
University of Minnesota Ph.D. dissertation. August 2014. Major: Physics. Advisor: Jeremiah Mans. 1 computer file (PDF); viii, 142 pages, appendix A.
DOI: 10.1088/1748-0221/11/11/p11018
2016
Liquid scintillator tiles for calorimetry
Future experiments in high energy and nuclear physics may require large, inexpensive calorimeters that can continue to operate after receiving doses of 50 Mrad or more. The light output of liquid scintillators suffers little degradation under irradiation. However, many challenges exist before liquids can be used in sampling calorimetry, especially regarding developing a packaging that has sufficient efficiency and uniformity of light collection, as well as suitable mechanical properties. We present the results of a study of a scintillator tile based on the EJ-309 liquid scintillator using cosmic rays and test beam on the light collection efficiency and uniformity, and some preliminary results on radiation hardness.
2016
Performance of the Prototype Readout System for the CMS Endcap Hadron Calorimeter Upgrade
2008
A Muon Veto Shielded Cavern for Underground Experiments and Shower Studies