ϟ

Martina Ressegotti

Here are all the papers by Martina Ressegotti that you can download and read on OA.mg.
Martina Ressegotti’s last known institution is . Download Martina Ressegotti PDFs here.

Claim this Profile →
DOI: 10.22323/1.449.0484
2024
Search for heavy, long-lived, charged particles with large ionisation energy loss and time-of-flight with the ATLAS experiment
We present a new search for hypothetical massive, charged, long-lived particles with the ATLAS detector at the LHC using an integrated luminosity of 140 fb$^{-1}$ of proton-proton collisions at $\sqrt{s}$=13 TeV. These particles are expected to move significantly slower than the speed of light and should be identifiable by their high transverse momenta and anomalously large specific ionisation losses measured in the pixel detector. This information can be used in combination with the speed measured by Time-of-Flight in the ATLAS calorimeters. Results are presented covering particles with lifetimes down to O(3) ns and with masses ranging from 200 GeV to 3 TeV. Interpretations for pair-production of R-hadrons and staus in scenarios of supersymmetry compatible with these particles being long-lived are presented, with mass limits extending beyond those from previous searches in broad ranges of lifetime.
DOI: 10.22323/1.448.0072
2024
Qualification of irradiated 3D pixel sensors produced by FBK for the pre-production of the ATLAS ITk detector
DOI: 10.1088/1748-0221/12/06/c06027
2017
Cited 14 times
The μ-RWELL detector
The μ-RWELL has been conceived as a compact, simple and robust Micro-Pattern-Gaseous-Detector (MPGD) for very large area HEP applications requiring the operation in harsh environment. The detector amplification stage, similar to a GEM foil, is realized with a polyimide structure micro-patterned with a blind-hole matrix, embedded through a thin Diamond Like Carbon (DLC) resistive layer in the readout PCB. The introduction of the resistive layer strongly suppressing the transition from streamer to spark gives the possibility to achieve large gains (> 104), without significantly affecting the capability to stand high particle fluxes. In this work we give an overview of the two detector layouts designed for low and high rate applications, presenting the results of a systematic study of the detector performance as a function of the surface resistivity and discussing the status of the Technology Transfer towards the industry for large area detector manufacturing.
DOI: 10.1088/1742-6596/1498/1/012015
2020
Cited 7 times
Diamond-Like Carbon for the Fast Timing MPGD
Abstract The present generation of Micro-Pattern Gaseous Detectors (MPGDs) are radiation hard detectors, capable of detecting effciently particle rates of several MHz/cm 2 , while exhibiting good spatial resolution (≤ 50 µm) and modest time resolution of 5-10 ns, which satisfies the current generation of experiments (High Luminosity LHC upgrades of CMS and ATLAS) but it is not sufficient for bunch crossing identification of fast timing systems at FCC-hh. Thanks to the application of thin resistive films such as Diamond-Like Carbon (DLC) a new detector concept was conceived: Fast Timing MPGD (FTM). In the FTM the drift volume of the detector has been divided in several layers each with their own amplification structure. The use of resistive electrodes makes the entire structure transparent for electrical signals. After some first initial encouraging results, progress has been slowed down due to problems with the wet-etching of DLC-coated polyimide foils. To solve these problems a more in-depth knowledge of the internal stress of the DLC together with the DLC-polyimide adhesion is required. We will report on the production of DLC films produced in Italy with Ion Beam Sputtering and Pulsed Laser Deposition, where we are searching to improve the adhesion of the thin DLC films, combined with a very high uniformity of the resistivity values.
DOI: 10.1088/1748-0221/14/11/c11012
2019
Cited 7 times
The CMS RPC detector performance and stability during LHC RUN-2
The CMS experiment, located at the Large Hadron Collider (LHC) in CERN, has a redundant muon system composed by three different gaseous detector technologies: Cathode Strip Chambers (in the forward regions), Drift Tubes (in the central region), and Resistive Plate Chambers (both its central and forward regions). All three are used for muon reconstruction and triggering. The CMS RPC system confers robustness and redundancy to the muon trigger. The RPC system operation in the challenging background and pileup conditions of the LHC environment is presented. The RPC system provides information to all muon track finders and thus contributing to both muon trigger and reconstruction. The summary of the detector performance results obtained with proton-proton collision at √s = 13 TeV during 2016 and 2017 data taking have been presented. The stability of the system is presented in terms of efficiency and cluster size vs time and increasing instantaneous luminosity. Data-driven predictions about the expected performance during High Luminosity LHC (HL-LHC) stage have been reported.
DOI: 10.1088/1748-0221/16/11/p11014
2021
Cited 4 times
Performance of a triple-GEM demonstrator in pp collisions at the CMS detector
After the Phase-2 high-luminosity upgrade to the Large Hadron Collider (LHC), the collision rate and therefore the background rate will significantly increase, particularly in the high $\eta$ region. To improve both the tracking and triggering of muons, the Compact Muon Solenoid (CMS) Collaboration plans to install triple-layer Gas Electron Multiplier (GEM) detectors in the CMS muon endcaps. Demonstrator GEM detectors were installed in CMS during 2017 to gain operational experience and perform a preliminary investigation of detector performance. We present the results of triple-GEM detector performance studies performed in situ during normal CMS and LHC operations in 2018. The distribution of cluster size and the efficiency to reconstruct high $p_T$ muons in proton--proton collisions are presented as well as the measurement of the environmental background rate to produce hits in the GEM detector.
DOI: 10.1088/1748-0221/13/08/p08024
2018
Cited 4 times
Long-term performance and longevity studies of the CMS Resistive Plate Chambers
Four double-gap CMS resistive plate chambers are being tested at the CERN Gamma Irradiation Facility to determine the performance and aging effects at the expected conditions of the High Luminosity-Large Hadron Collider. Results up to an integrated charge of 290 millicoulomb/cm2 are reported.
DOI: 10.1088/1748-0221/13/09/c09001
2018
Cited 3 times
Fast timing measurement for CMS RPC Phase-II upgrade
With the increase of the LHC luminosity foreseen in the coming years, many detectors currently used in the different LHC experiments will be dramatically impacted and some need to be replaced or upgraded. The new ones should be capable to provide time information to reduce the data ambiguity due to the expected high pileup. We propose to equip CMS high |η| muon chambers with pairs of single gap RPC detectors read out by long pickup strips PCB. The precise time measurement (0<15 ps) of the signal induced by particles crossing the detector on both ends of each strip will give an accurate measurement of the position of the incoming particle along the strip. The absolute time measurement, determined by RPC signal (around 1.5 ns) will also reduce the data ambiguity due to the highly expected pileup and help to identify Heavy Stable Charged Particles (HSCP). The development of a specific electronic chain (analog front-end ASIC, time-to-digital converter stage and printed circuit board design) and the corresponding first results on prototype chambers are presented.
DOI: 10.1088/1748-0221/14/09/c09045
2019
Cited 3 times
RPC radiation background simulations for the high luminosity phase in the CMS experiment
The high luminosity expected from the HL-LHC will be a challenge for the CMS detector. The increased rate of particles coming from the collisions and the radioactivity induced in the detector material could cause significant damage and result in a progressive degradation of its performance. Simulation studies are very useful in these scenarios as they allow one to study the radiation environment and the impact on detector performance. Results are presented for CMS RPC stations considering the operating conditions expected at the HL-LHC.
DOI: 10.22323/1.420.0025
2023
Qualification of the first pre-production 3D FBK sensors with ITkPixV1 readout chip
The ITk detector, the new ATLAS silicon tracking system for the High Luminosity LHC (HL-LHC), will be equipped with 3D pixel sensor modules in the innermost layer (L0).The pixel cell dimensions will be 25×100 µm 2 in the barrel and 50×50 µm 2 in the end-caps, with one readout electrode at the centre of each pixel and four bias electrodes at the corners.Sensors from pre-production wafers (50×50 µm 2 ) produced by FBK have been bump-bonded to ITkPixV1.1 chips at IZM. Bare modules have been assembled in Genoa on Single Chip Cards (SCCs) and characterized in laboratory measurements and in test beam campaigns.Some of these modules have been irradiated in Bonn and at the CERN IRRAD facility.Preliminary results of their characterization after irradiation are shown, including measurements performed during test beam campaigns at CERN SPS in Summer 2022.
DOI: 10.1088/1748-0221/14/10/c10027
2019
RE3/1 &amp; RE4/1 RPC chambers integration in the inner region of the forward muon spectrometer in the CMS experiment
The high pseudorapidity ($\eta$) region of the Compact Muon Solenoid (CMS) muon system is covered by Cathode Strip Chambers only and lacks redundant coverage despite the fact that it is a challenging region for muons in terms of backgrounds and momentum resolution. During the annual Year-End Technical Stops 2022 & 2023, two new layers of improved Resistive Plate Chambers (iRPC) will be added, RE3/1 & RE4/1, which will completely cover the region of $1.8 < |\eta| < 2.4$ in the endcap. Thus, the additional new chambers will lead to increase efficiency for both trigger and offline reconstruction in the difficult region where the background is the highest and the magnetic field is the lowest within the muon system. The extended RPC system will improve the performance and the robustness of the muon trigger. The final design of iRPC chambers and the concept to integrate and install them in the CMS muon system have been finalized. In this report, the main results demonstrating the implementation and installation of the new iRPC detectors in the CMS muon system at high $|\eta|$ region will be presented.
DOI: 10.22323/1.302.0002
2017
Advances on micro-RWELL gaseous detector
The R&D on the micro-Resistive-WELL (µ-RWELL) detector technology aims in developing a new scalable, compact, spark-protected, single amplification stage Micro-Pattern Gas Detectors (MPGD) for large area HEP applications as tracking and calorimeter device as well as for industrial and medical applications as X-ray and neutron imaging gas pixel detector.The novel microstructure, exploiting several solutions and improvements achieved in the last years for MPGDs, in particular for GEMs and Micromegas, is an extremely simple detector allowing an easy engineering with consequent technological transfer toward the photolithography industry.Large area detectors (up 1×2 m 2 ) can be realized splicing µ-RWELL_PCB tiles of smaller size (about 0.5×1 m 2 -typical PCB industrial size).The detector, composed by few basic elements such as the readout-PCB embedded with the amplification stage (through the resistive layer) and the cathode defining the gas drift-conversion gap has been largely characterized on test bench with X-ray and with beam test.
DOI: 10.1088/1748-0221/14/05/c05012
2019
Longevity studies on the CMS-RPC system
In the next decades, the Large Hadron Collider (LHC) will run at very high luminosity (HL-LHC) 5×1034 cm−2s−1, factor five more than the nominal LHC luminosity. During this period the CMS RPC system will be subjected to high background rates which could affect the performance by inducing aging effects. A dedicated longevity program to qualify the present RPC system for the HL-LHC running period is ongoing. At the CERN Gamma Irradiation Facility (GIF++) four RPC detectors, from the spare production, are exposed to an intense gamma radiation for a dose equivalent to the one expected at the HL-LHC . The main detector parameters are under monitoring as a function of the integrated charge and the performance is studied with a muon beam. Preliminary results of the study after having collected ≈ 34% of the expected integrated charge will be presented.
DOI: 10.1088/1748-0221/14/09/c09046
2019
High voltage calibration method for the CMS RPC detector
The Resistive Plate Chambers (RPC) are used for muon triggers in the CMS experiment. To calibrate the high voltage working-points (WP) and identify degraded detectors due to radiation or chemical damage, a high voltage scan has been performed using 2017 data from pp collisions at a center-of-mass energy of 13 TeV. In this paper, we present the calibration method and the latest results obtained for the 2017 data. A comparison with all scans taken since 2011 is considered to investigate the stability of the detector performance in time.
2019
Micropattern Gas Detectors for the CMS Experiment's Muon System Upgrade: Performance Studies and Commissioning of the first GEM Detectors
DOI: 10.1088/1748-0221/15/05/c05072
2020
RPC upgrade project for CMS Phase II
The Muon Upgrade Phase II of the Compact Muon Solenoid (CMS) aims to guarantee the optimal conditions of the present system and extend the η coverage to ensure a reliable system for the High Luminosity Large Hadron Collider (HL-LHC) period. The Resistive Plate Chambers (RPCs) system will upgrade the off-detector electronics (called link system) of the chambers currently installed chambers and place improved RPCs (iRPCs) to cover the high pseudo−rapidity region, a challenging region for muon reconstruction in terms of background and momentum resolution. In order to find the best option for the iRPCs, an R&D program for new detectors was performed and real size prototypes have been tested in the Gamma Irradiation Facility (GIF++) at CERN. The results indicated that the technology suitable for the high background conditions is based on High Pressure Laminate (HPL) double-gap RPC. The RPC Upgrade Phase II program is planned to be ready after the Long Shutdown 3 (LS3).
2021
arXiv : Modeling the triple-GEM detector response to background particles for the CMS Experiment
An estimate of environmental background hit rate on triple-GEM chambers is performed using Monte Carlo (MC) simulation and compared to data taken by test chambers installed in the CMS experiment (GE1/1) during Run-2 at the Large Hadron Collider (LHC). The hit rate is measured using data collected with proton-proton collisions at 13 TeV and a luminosity of 1.5$\times10^{34}$ cm$^{-2}$ s$^{-1}$. The simulation framework uses a combination of the FLUKA and Geant4 packages to obtain the hit rate. FLUKA provides the radiation environment around the GE1/1 chambers, which is comprised of the particle flux with momentum direction and energy spectra ranging from $10^{-11}$ to $10^{4}$ MeV for neutrons, $10^{-3}$ to $10^{4}$ MeV for $\gamma$'s, $10^{-2}$ to $10^{4}$ MeV for $e^{\pm}$, and $10^{-1}$ to $10^{4}$ MeV for charged hadrons. Geant4 provides an estimate of detector response (sensitivity) based on an accurate description of detector geometry, material composition and interaction of particles with the various detector layers. The MC simulated hit rate is estimated as a function of the perpendicular distance from the beam line and agrees with data within the assigned uncertainties of 10-14.5%. This simulation framework can be used to obtain a reliable estimate of background rates expected at the High Luminosity LHC.
DOI: 10.1088/1748-0221/12/07/c07003
2017
A new design using GEM-based technology for the CMS experiment
The muon system of the Compact Muon Solenoid (CMS) experiment at the LHC is currently not instrumented for pseudorapidity higher than |η|> 2.4. The main challenges to the installation of a detector in that position are the high particle flux to be sustained, a high level of radiation, and the ability to accomodate a multilevel detector into the small available space (less than 30 cm). A new back-to-back configuration of a Gas Electron Multiplier (GEM) detector is presented with the aim of developing a compact, multi-layer GEM detector. It is composed of two independent stacked triple-GEM detectors, positioned with the anodes toward the outside and sharing the same cathode plane, which is located at the center of the chamber, to reduce the total detector's thickness. A first prototype has been produced and tested with an X-Ray source and muon beam. First results on its performance are presented.
DOI: 10.1088/1742-6596/934/1/012052
2017
Commissioning of the first chambers of the CMS GE1/1 muon station
The upgrades of the LHC planned in the next years will increase the instantaneous luminosity up to 5 × 1034 cm−2s−1 after Long Shutdown 3, a value about five times higher than the nominal one for which the CMS experiment was designed. The resulting larger rate of interactions will produce a higher pileup environment that will challenge the trigger system of the CMS experiment in its original configuration, in particular in the endcap region. As part of the upgrade program of the CMS muon endcaps, additional muon detectors based on Gas Electron Multiplier (GEM) technology will be installed, in order to be able to sustain a physics program during high-luminosity operation without performance losses. The installation of the GE1/1 station is scheduled for Long Shutdown 2 in 2019–2020; already a demonstrator composed of five superchambers has been installed during the Extended Year-End Technical Stop at the beginning of 2017. Its goal is to test the system's operational conditions and also to demonstrate the integration of the GE1/1 chambers into the CMS online system. The status of the installation and commissioning of the GE1/1 demonstrator is presented.
DOI: 10.3390/universe5010018
2019
Overview of the CMS Detector Performance at LHC Run 2
The Compact Muon Solenoid (CMS) detector is one of the two multipurpose experiments at the Large Hadron Collider (LHC). It has successfully collected data during Run 1 (2010–2013) and achieved important physics results, like the discovery of the Higgs boson announced in 2012. Willing to unravel further open questions not yet explained by the standard model, intense activities have been performed to further improve the detector and the trigger before the LHC restart in 2016 (Run 2), in parallel with the upgrade of the LHC. The achieved global performance of the CMS experiment and of several subdetectors will be presented.
2018
RPC upgrade project for CMS Phase II : arXiv
DOI: 10.1109/nssmic.2018.8824284
2018
Simulation studies on the muon triggering capability of the ME0 GEM station in the CMS experiment
The CMS muon system is designed to be highly redundant in order to provide good momentum estimation and an efficient trigger selection. Redundancy will be even more important during the High Luminosity operation of the LHC (HL-LHC). On the other hand, the forward region of the CMS muon system has less redundancy in the very high pseudora-pidity region. Several upgrades for HL-LHC based on different technologies are planned to overcome this weakness, including the installation of several stations of GEM based muon detectors. Among these, the ME0 station will not only improve redundancy and trigger efficiency, but also extend the muon system coverage to higher pseudorapidity. This will increase the acceptance for forward muons in final states of new physics. The ME0 station will be composed of six layers of GEM detectors, in order to make up for the dearth of information in the high pseudorapidity region. A specific trigger is being developed and needs to be integrated into CMS, using the lepton flavour violation decay of τ → 3μ as a benchmark physics scenario. The current status of this study is described.
DOI: 10.1088/1748-0221/14/10/c10020
2019
CMS RPC efficiency measurement using the tag-and-probe method
We measure the efficiency of CMS Resistive Plate Chamber (RPC) detectors in proton-proton collisions at the centre-of-mass energy of 13 TeV using the tag-and-probe method. A muon from a Z0 boson decay is selected as a probe of efficiency measurement, reconstructed using the CMS inner tracker and the rest of CMS muon systems. The overall efficiency of CMS RPC chambers during the 2016–2017 collision runs is measured to be more than 96% for the nominal RPC chambers.
DOI: 10.1088/1748-0221/14/11/c11011
2019
Search for Heavy Stable Charged Particles in the CMS Experiment using the RPC Phase II upgraded detectors
Several theoretical models inspired by the idea of supersymmetry (SUSY) accommodate the possibility of Heavy Stable Charged Particles (HSCPs). The Phase II upgrade of the CMS-RPC system will allow the trigger and identification of this kind of particles exploiting the Time-of-Flight Technique with the improved time resolution that a new Data Acquisition System (DAQ) system will provide (∼2 ns). Moreover, new Resistive Plate Chambers (RPC) detector chambers will be installed to extend the acceptance coverage up to |η|<2.4 with similar time resolution and better spatial resolution. We present a trigger strategy to detect HSCPs with the RPC detectors. Its performance is studied with Monte Carlo simulations and the expected results with the High Luminosity Large Hadron Collider (HL-LHC) data are shown.
DOI: 10.1088/1748-0221/14/10/c10037
2019
High Rate RPC detector for LHC
The High Luminosity LHC (HL-LHC) phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. The foreseen gradual increase of the instantaneous luminosity of up to more than twice its nominal value of $10\times10^{34}\ {\rm cm}^{-1}{\rm s}^{-2}$ during Phase I and Phase II of the LHC running, presents special challenges for the experiments. The region with high pseudo rapidity ($\eta$) region of the forward muon spectrometer ($2.4 > |\eta| > 1.9$) is not equipped with RPC stations. The increase of the expected particles rate up to 2 kHz cm$^{-1}$ ( including a safety factor 3 ) motivates the installation of RPC chambers to guarantee redundancy with the CSC chambers already present. The current CMS RPC technology cannot sustain the expected background level. A new generation of Glass-RPC (GRPC) using low-resistivity glass was proposed to equip the two most far away of the four high $\eta$ muon stations of CMS. In their single-gap version they can stand rates of few kHz cm$^{-1}$. Their time precision of about 1 ns can allow to reduce the noise contribution leading to an improvement of the trigger rate. The proposed design for large size chambers is examined and some preliminary results obtained during beam tests at Gamma Irradiation Facility (GIF++) and Super Proton Synchrotron (SPS) at CERN are shown. They were performed to validate the capability of such detectors to support high irradiation environment with limited consequence on their efficiency.