ϟ

K. Höepfner

Here are all the papers by K. Höepfner that you can download and read on OA.mg.
K. Höepfner’s last known institution is . Download K. Höepfner PDFs here.

Claim this Profile →
DOI: 10.1016/j.dark.2019.100371
2020
Cited 149 times
Dark Matter benchmark models for early LHC Run-2 Searches: Report of the ATLAS/CMS Dark Matter Forum
This document is the final report of the ATLAS-CMS Dark Matter Forum, a forum organized by the ATLAS and CMS collaborations with the participation of experts on theories of Dark Matter, to select a minimal basis set of dark matter simplified models that should support the design of the early LHC Run-2 searches. A prioritized, compact set of benchmark models is proposed, accompanied by studies of the parameter space of these models and a repository of generator implementations. This report also addresses how to apply the Effective Field Theory formalism for collider searches and present the results of such interpretations.
DOI: 10.1016/s0168-9002(97)00931-5
1997
Cited 210 times
The CHORUS experiment to search for νμ → ντ oscillation
A new experimental apparatus, designed principally for a high sensitivity search for νμ → ντ oscillation, has been successlly constructed and made operational by the CHORUS Collaboration for the CERN-WA95 experiment. It consists of a large emulsion target, a scintillating fiber tracker system with optoelectronics read-out, an air-core magnet, a set of trigger hodoscopes, a calorimeter based on the lead/scintillating-fiber technique, and a muon spectrometer. The design, construction and performance of the entire apparatus and of the different detectors are described.
DOI: 10.1007/978-3-642-13271-1_19
2012
Cited 33 times
Muon Spectrometers
DOI: 10.1016/j.nima.2022.166716
2022
Cited 10 times
Quality control of mass-produced GEM detectors for the CMS GE1/1 muon upgrade
The series of upgrades to the Large Hadron Collider, culminating in the High Luminosity Large Hadron Collider, will enable a significant expansion of the physics program of the CMS experiment. However, the accelerator upgrades will also make the experimental conditions more challenging, with implications for detector operations, triggering, and data analysis. The luminosity of the proton-proton collisions is expected to exceed $2-3\times10^{34}$~cm$^{-2}$s$^{-1}$ for Run 3 (starting in 2022), and it will be at least $5\times10^{34}$~cm$^{-2}$s$^{-1}$ when the High Luminosity Large Hadron Collider is completed for Run 4. These conditions will affect muon triggering, identification, and measurement, which are critical capabilities of the experiment. To address these challenges, additional muon detectors are being installed in the CMS endcaps, based on Gas Electron Multiplier technology. For this purpose, 161 large triple-Gas Electron Multiplier detectors have been constructed and tested. Installation of these devices began in 2019 with the GE1/1 station and will be followed by two additional stations, GE2/1 and ME0, to be installed in 2023 and 2026, respectively. The assembly and quality control of the GE1/1 detectors were distributed across several production sites around the world. We motivate and discuss the quality control procedures that were developed to standardize the performance of the detectors, and we present the final results of the production. Out of 161 detectors produced, 156 detectors passed all tests, and 144 detectors are now installed in the CMS experiment. The various visual inspections, gas tightness tests, intrinsic noise rate characterizations, and effective gas gain and response uniformity tests allowed the project to achieve this high success rate.
DOI: 10.1016/0168-9002(95)00734-2
1995
Cited 47 times
Performance and calibration of the CHORUS scintillating fiber tracker and opto-electronics readout system
An essential component of the CERN WA95/CHORUS experiment is a scintillating fiber tracker system for precise track reconstruction of particles. The tracker design, its opto-electronics readout and calibration system are discussed. Performances of the detector are presented.
DOI: 10.48550/arxiv.1902.04070
2019
Cited 18 times
Standard Model Physics at the HL-LHC and HE-LHC
The successful operation of the Large Hadron Collider (LHC) and the excellent performance of the ATLAS, CMS, LHCb and ALICE detectors in Run-1 and Run-2 with $pp$ collisions at center-of-mass energies of 7, 8 and 13 TeV as well as the giant leap in precision calculations and modeling of fundamental interactions at hadron colliders have allowed an extraordinary breadth of physics studies including precision measurements of a variety physics processes. The LHC results have so far confirmed the validity of the Standard Model of particle physics up to unprecedented energy scales and with great precision in the sectors of strong and electroweak interactions as well as flavour physics, for instance in top quark physics. The upgrade of the LHC to a High Luminosity phase (HL-LHC) at 14 TeV center-of-mass energy with 3 ab$^{-1}$ of integrated luminosity will probe the Standard Model with even greater precision and will extend the sensitivity to possible anomalies in the Standard Model, thanks to a ten-fold larger data set, upgraded detectors and expected improvements in the theoretical understanding. This document summarises the physics reach of the HL-LHC in the realm of strong and electroweak interactions and top quark physics, and provides a glimpse of the potential of a possible further upgrade of the LHC to a 27 TeV $pp$ collider, the High-Energy LHC (HE-LHC), assumed to accumulate an integrated luminosity of 15 ab$^{-1}$.
DOI: 10.1016/s0370-2693(98)00081-1
1998
Cited 38 times
A search for νμ→ντ oscillation
CHORUS is an experiment searching for νμ→ντ oscillation in the CERN wide band neutrino beam with a hybrid setup consisting of a nuclear emulsion target followed by electronic detectors. The experiment has been taking data from 1994 through 1997. A subset of the neutrino interactions collected in 1994 and 1995 have been analyzed, looking for ντ charged current interactions where the τ lepton decays to μν̄μντ. In a sample of 31,423 νμ charged current interactions, no ντ candidates were found. For large Δm2μτ values, a limit on the mixing angle of sin22θμτ<3.5×10−3 at 90% C.L. can be set, thus improving the previous best result.
DOI: 10.1088/1748-0221/9/10/c10036
2014
Cited 18 times
Upgrade of the CMS muon system with triple-GEM detectors
The CMS collaboration considers upgrading the muon forward region which is particularly affected by the high-luminosity conditions at the LHC. The proposal involves Gas Electron Multiplier (GEM) chambers, which are able to handle the extreme particle rates expected in this region along with a high spatial resolution. This allows to combine tracking and triggering capabilities, which will improve the CMS muon High Level Trigger, the muon identification and the track reconstruction. Intense R&D has been going on since 2009 and it has lead to the development of several GEM prototypes and associated detector electronics. These GEM prototypes have been subjected to extensive tests in the laboratory and in test beams at the CERN Super Proton Synchrotron (SPS). This contribution will review the status of the CMS upgrade project with GEMs and its impact on the CMS performance.
DOI: 10.1016/j.nima.2018.11.061
2019
Cited 16 times
Layout and assembly technique of the GEM chambers for the upgrade of the CMS first muon endcap station
Triple-GEM detector technology was recently selected by CMS for a part of the upgrade of its forward muon detector system as GEM detectors provide a stable operation in the high radiation environment expected during the future High-Luminosity phase of the Large Hadron Collider (HL-LHC). In a first step, GEM chambers (detectors) will be installed in the innermost muon endcap station in the $1.6<\left|\eta\right|<2.2$ pseudo-rapidity region, mainly to control level-1 muon trigger rates after the second LHC Long Shutdown. These new chambers will add redundancy to the muon system in the $\eta$-region where the background rates are high, and the bending of the muon trajectories due to the CMS magnetic field is small. A novel construction technique for such chambers has been developed in such a way where foils are mounted onto a single stack and then uniformly stretched mechanically, avoiding the use of spacers and glue inside the active gas volume. We describe the layout, the stretching mechanism and the overall assembly technique of such GEM chambers.
DOI: 10.1016/j.nima.2023.168103
2023
The Analytical Method algorithm for trigger primitives generation at the LHC Drift Tubes detector
The Compact Muon Solenoid (CMS) experiment prepares its Phase-2 upgrade for the high-luminosity era of the LHC operation (HL-LHC). Due to the increase of occupancy, trigger latency and rates, the full electronics of the CMS Drift Tube (DT) chambers will need to be replaced. In the new design, the time bin for the digitization of the chamber signals will be of around 1 ns, and the totality of the signals will be forwarded asynchronously to the service cavern at full resolution. The new backend system will be in charge of building the trigger primitives of each chamber. These trigger primitives contain the information at chamber level about the muon candidates position, direction, and collision time, and are used as input in the L1 CMS trigger. The added functionalities will improve the robustness of the system against ageing. An algorithm based on analytical solutions for reconstructing the DT trigger primitives, called Analytical Method, has been implemented both as a software C++ emulator and in firmware. Its performance has been estimated using the software emulator with simulated and real data samples, and through hardware implementation tests. Measured efficiencies are 96 to 98% for all qualities and time and spatial resolutions are close to the ultimate performance of the DT chambers. A prototype chain of the HL-LHC electronics using the Analytical Method for trigger primitive generation has been installed during Long Shutdown 2 of the LHC and operated in CMS cosmic data taking campaigns in 2020 and 2021. Results from this validation step, the so-called Slice Test, are presented.
DOI: 10.1016/s0920-5632(97)00592-6
1998
Cited 36 times
Tracking with capillaries and liquid scintillator
The technique of glass capillaries filled with liquid scintillator allows the reconstruction of ionizing particle tracks with high spatial resolution. Detectors based on this technique consist of coherent arrays of capillaries having diameters of the order of 20 μm. Light signals are amplified by an optoelectronic chain composed of a series of image intensifiers: the readout is performed through a CCD. The ongoing research in the field of liquid scintillators has led to excellent results in terms of information density (≥ 5 hits/mm) and radiation resistance (order of 1 MGy). In this paper new results about the effect of ageing and purification of liquid scintillators will be presented. The RD46 collaboration has developed a completely new detector having a readout chain composed of only one image intensifier followed by a new device: a Megapixel Electron Bombarded CCD. First images of neutrino interactions will be shown, together with preliminary measurements of the resolution of the detector.
DOI: 10.1016/s0370-2693(98)00781-3
1998
Cited 34 times
Search for νμ→ντ oscillation using the τ decay modes into a single charged particle
Part of the neutrino events collected in 1994-1995 by the CHORUS experiment has been analysed. A search was performed for ντ charged current interactions followed by the τ lepton decay into a single charged negative hadron, a possible indication for νμ→ντ oscillation. A sample of 6844 events without an identified muon has been located in the emulsion target. Within the selection criteria, no τ− candidate has been found. Combining this result with the one from the search for ντ interactions using the muonic decay mode (36 182 events with an identified muon), a 90% C.L. limit on the mixing angle sin22θμτ<1.8·10−3 (at large Δm2) has been derived.
DOI: 10.1016/j.nima.2004.06.169
2004
Cited 27 times
Bunched beam test of the CMS drift tubes local muon trigger
The 40 MHz bunched muon beam set up at CERN was used in May 2003 to make a full test of the drift tubes local muon trigger. The main goal of the test was to prove that the integration of the various devices located on a muon chamber was adequately done both on the hardware and software side of the system. Furthermore the test provided complete information about the general performance of the trigger algorithms in terms of efficiency and noise. Data were collected with the default configuration of the trigger devices and with several alternative configurations at various angles of incidence of the beam. Tests on noise suppression and di-muon trigger capability were performed.
DOI: 10.48550/arxiv.1812.07638
2018
Cited 14 times
Opportunities in Flavour Physics at the HL-LHC and HE-LHC
Motivated by the success of the flavour physics programme carried out over the last decade at the Large Hadron Collider (LHC), we characterize in detail the physics potential of its High-Luminosity and High-Energy upgrades in this domain of physics. We document the extraordinary breadth of the HL/HE-LHC programme enabled by a putative Upgrade II of the dedicated flavour physics experiment LHCb and the evolution of the established flavour physics role of the ATLAS and CMS general purpose experiments. We connect the dedicated flavour physics programme to studies of the top quark, Higgs boson, and direct high-$p_T$ searches for new particles and force carriers. We discuss the complementarity of their discovery potential for physics beyond the Standard Model, affirming the necessity to fully exploit the LHC's flavour physics potential throughout its upgrade eras.
DOI: 10.1088/1748-0221/11/01/c01023
2016
Cited 12 times
Design of a constant fraction discriminator for the VFAT3 front-end ASIC of the CMS GEM detector
In this work the design of a constant fraction discriminator (CFD) to be used in the VFAT3 chip for the read-out of the triple-GEM detectors of the CMS experiment, is described. A prototype chip containing 8 CFDs was implemented using 130 nm CMOS technology and test results are shown.
DOI: 10.1016/s0168-9002(98)00276-9
1998
Cited 24 times
The CHORUS scintillating fiber tracker and opto-electronic readout system
A scintillating fiber tracker system consisting of more than one million fibers has been successfully constructed and made operational for the CERN WA95/CHORUS experiment. The design and construction of the tracker system as well as its opto-electronic readout are described. The performance of the detector with high-energy muons is presented.
DOI: 10.1016/j.nima.2020.164104
2020
Cited 8 times
Performance of prototype GE1<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline" id="d1e1083" altimg="si14.svg"><mml:mo>∕</mml:mo></mml:math>1 chambers for the CMS muon spectrometer upgrade
The high-luminosity phase of the Large Hadron Collider (HL-LHC) will result in ten times higher particle background than measured during the first phase of LHC operation. In order to fully exploit the highly-demanding operating conditions during HL-LHC, the Compact Muon Solenoid (CMS) Collaboration will use Gas Electron Multiplier (GEM) detector technology. The technology will be integrated into the innermost region of the forward muon spectrometer of CMS as an additional muon station called GE1∕1. The primary purpose of this auxiliary station is to help in muon reconstruction and to control level-1 muon trigger rates in the pseudo-rapidity region 1.6≤|η|≤2.2. The new station will contain trapezoidal-shaped GEM detectors called GE1∕1 chambers. The design of these chambers is finalized, and the installation is in progress during the Long Shutdown phase two (LS-2) that started in 2019. Several full-size prototypes were built and operated successfully in various test beams at CERN. We describe performance measurements such as gain, efficiency, and time resolution of these prototype chambers, developed after years of R&D, and summarize their behavior in different gas compositions as a function of the applied voltage.
DOI: 10.1140/epjc/s10052-008-0674-7
2008
Cited 11 times
Reconstruction of cosmic and beam-halo muons with the CMS detector
The powerful muon and tracker systems of the CMS detector together with dedicated reconstruction software allow precise and efficient measurement of muon tracks originating from proton-proton collisions. The standard muon reconstruction algorithms, however, are inadequate to deal with muons that do not originate from collisions. This note discusses the design, implementation, and performance results of a dedicated cosmic muon track reconstruction algorithm, which features pattern recognition optimized for muons that are not coming from the interaction point, i.e., cosmic muons and beam-halo muons. To evaluate the performance of the new algorithm, data taken during Cosmic Challenge phases I and II were studied and compared with simulated cosmic data. In addition, a variety of more general topologies of cosmic muons and beam-halo muons were studied using simulated data to demonstrate some key features of the new algorithm.
DOI: 10.1088/1748-0221/8/12/c12031
2013
Cited 9 times
Status of the Triple-GEM project for the upgrade of the CMS Muon System
The CMS GEM collaboration is performing a feasibility study to install triple-GEM detectors in the forward region of the muon system (1.6 < |η| < 2.4) of the CMS detector at the LHC. Such micro-pattern gas detectors are able to cope with the extreme particle rates that are expected in that region during the High Luminosity phase of the LHC. With their spatial resolution of order 100 micron GEMs would not only provide additional benefits in the CMS muon High Level Trigger, but also in the muon identification and track reconstruction, effectively combining tracking and triggering capabilities in one single device. The present status of the full project will be reviewed, highlighting all importants steps and achievements since the start of the R&amp;D in 2009. Several small and full-size prototypes were constructed with different geometries and techniques. The baseline design of the triple-GEM detector for CMS will be described, along with the results from extensive test measurements of all prototypes both in the lab and in test beams at the CERN SPS. The proposed on- and off-detector electronics for the final system will be presented.
DOI: 10.1016/j.nima.2016.05.067
2017
Cited 9 times
R&amp;D on a new type of micropattern gaseous detector: The Fast Timing Micropattern detector
This contribution introduces a new type of Micropattern Gaseous Detector, the Fast Timing Micropattern (FTM) detector, utilizing fully Resistive WELL structures. The structure of the prototype will be described in detail and the results of the characterization study performed with an X-ray gun will be presented, together with the first results on time resolution based on data collected with muon/pion test beams.
DOI: 10.1016/0168-9002(94)01214-8
1995
Cited 18 times
Development of large-volume, high-resolution tracking detectors based on capillaries filled with liquid scintillator
Searches for the decay of short-lived particles require real time, high-resolution tracking in active targets, which in the case of neutrino physics should be of large volume. The possibility of achieving this by using glass capillaries filled with organic liquid scintillator is being investigated in the framework of the CHORUS experiment at CERN. In this paper, after outlining the application foreseen, advances in the tracking technique are discussed and results from tests are reported. An active target of dimensions 180 × 2 × 2 cm3 has been assembled from capillaries with 20 μm diameter pores. The readout scheme currently in operation allows the reading of ∼ 5 × 105 channels using a single chain of image intensifiers having a resolution of σ ∼ 20 μm. Following the development of new liquid scintillators and purification methods an attenuation length of ∼3 m has been obtained. This translates into a hit density of 3.5 per mm for a minimum-ionizing particle that crosses the active target at a distance of 1 m from the readout end.
DOI: 10.1016/j.nima.2004.01.080
2004
Cited 13 times
Test beam analysis of the first CMS drift tube muon chamber
In October 2001 the first produced CMS Barrel Drift Tube (DT) Muon Chamber was tested at the CERN Gamma Irradiation Facility (GIF) using a muon beam. A Resistive Plate Chamber (RPC) was attached to the top of the DT chamber, and, for the first time, both detectors were operated coupled together. The performance of the DT chamber was studied for several operating conditions, and for gamma rates similar to the ones expected at LHC. In this paper we present the data analysis; the results are considered fully satisfactory.
2007
Cited 11 times
Simulation of Cosmic Muons and Comparison with Data from the Cosmic Challenge using Drift Tube Chambers
DOI: 10.1088/1748-0221/10/03/c03039
2015
Cited 7 times
Quality control and beam test of GEM detectors for future upgrades of the CMS muon high rate region at the LHC
Gas Electron Multipliers (GEM) are a proven position sensitive gas detector technology which nowadays is becoming more widely used in High Energy Physics. GEMs offer an excellent spatial resolution and a high particle rate capability, with a close to 100% detection efficiency. In view of the high luminosity phase of the CERN Large Hadron Collider, these aforementioned features make GEMs suitable candidates for the future upgrades of the Compact Muon Solenoid (CMS) detector. In particular, the CMS GEM Collaboration proposes to cover the high-eta region of the muon system with large-area triple-GEM detectors, which have the ability to provide robust and redundant tracking and triggering functions. In this contribution, after a general introduction and overview of the project, the construction of full-size trapezoidal triple-GEM prototypes will be described in more detail. The procedures for the quality control of the GEM foils, including gain uniformity measurements with an x-ray source will be presented. In the past few years, several CMS triple-GEM prototype detectors were operated with test beams at the CERN SPS. The results of these test beam campaigns will be summarised.
DOI: 10.1016/j.nima.2007.06.007
2007
Cited 8 times
Results of the first integration test of the CMS drift tubes muon trigger
Two drift tubes (DTs) chambers of the CMS muon barrel system were exposed to a 40 MHz bunched muon beam at the CERN SPS, and for the first time the whole CMS Level-1 DTs-based trigger system chain was tested. Data at different energies and inclination angles of the incident muon beam were collected, as well as data with and without an iron absorber placed between the two chambers, to simulate the electromagnetic shower development in CMS. Special data-taking runs were dedicated to test for the first time the Track Finder system, which reconstructs track trigger candidates by performing a proper matching of the muon segments delivered by the two chambers. The present paper describes the results of these measurements.
DOI: 10.1016/s0168-9002(99)01295-4
2000
Cited 11 times
High-resolution tracking using large capillary bundles filled with liquid scintillator
We have developed large high-resolution tracking detectors based on glass capillaries filled with organic liquid scintillator of high refractive index. These liquid-core scintillating optical fibres act simultaneously as detectors of charged particles and as image guides. Track images projected onto the readout end of a capillary bundle are visualized by an optoelectronic chain consisting of a set of image-intensifier tubes followed by a photosensitive CCD or by an EBCCD camera. Two prototype detectors, each composed of ≈106 capillaries with 20–25μm diameter and 0.9–1.8 m length, have been tested, and a spatial resolution of the order of 20–40μm has been attained. A high scintillation efficiency and a large light-attenuation length, in excess of 3 m, was achieved through special purification of the liquid scintillator. Along the tracks of minimum-ionizing particles, the hit densities obtained were ∼8hits/mm at the readout window, and ∼3hits/mm at ∼1m away. The level of radiation resistance of the prototype detectors is at least an order of magnitude higher than that of other tracking devices of comparable performance.
DOI: 10.1088/1748-0221/9/04/c04022
2014
Cited 4 times
A study of film and foil materials for the GEM detector proposed for the CMS muon system upgrade
During the next shutdown of the LHC at CERN, the CMS experiment plans to start installing GEM detectors in the endcap (high pseudorapidity) region. These muon detectors have excellent spatial and temporal resolution as well as a high chemical stability and radiation hardness. A report is given on preliminary results of materials studies that aimed to fully characterize the GEM detector components before and after the exposure to a high-radiation environment.
DOI: 10.1088/1748-0221/9/01/c01053
2014
Cited 4 times
Studies on the upgrade of the muon system in the forward region of the CMS experiment at LHC with GEMs
The LHC data-taking will resume in 2015 with energy of 13–14 TeV and luminosity of 2÷5 × 1034 cm−2 s−1. At those energies, a considerable fraction of the particles produced propagate in the high pseudo-rapidity regions. The proposal for the upgrade of the CMS muon forward system involves Gas Electron Multiplier (GEM) chambers to be installed during the second LHC Long Shutdown (LS2) covering the pseudorapidity range 1.5 < |η| < 2.2. This detector is able to handle the extreme particle rates expected in this region when the LHC will be running at higher luminosity. The GEM is an excellent choice, as its high spatial resolution (order of 100 μm) allows to combine tracking and triggering capabilities, which will improve the CMS muon High Level Trigger, the muon identification and the track reconstruction. Intense R&D has been going on since 2009 and it has lead to the development of several GEM prototypes and associated detector electronics. These GEM prototypes have been subjected to extensive tests in the laboratory and in test beams at the CERN Super Proton Synchrotron (SPS). This contribution will review the status of the CMS upgrade project with GEMs, discussing also the trigger performance.
DOI: 10.1088/1748-0221/8/11/c11017
2013
Cited 4 times
Development and performance of large scale triple GEM for CMS
The international CMS GEM collaboration is studying the feasibility of upgrading the CMS forward muon system by adding layers of triple GEM based detectors. After successful tests of small size tripe-GEM chambers in the period of 2010-2011, the collaboration has designed, built and tested full-size GEM chambers for the upgrade purpose. We report on results from test beam and simulation that were conducted to study the performance of the GEM chambers.
DOI: 10.1016/j.nima.2016.05.127
2017
Cited 4 times
Overview of large area triple-GEM detectors for the CMS forward muon upgrade
In order to cope with the harsh environment expected from the high luminosity LHC, the CMS forward muon system requires an upgrade. The two main challenges expected in this environment are an increase in the trigger rate and increased background radiation leading to a potential degradation of the particle ID performance. Additionally, upgrades to other subdetectors of CMS allow for extended coverage for particle tracking, and adding muon system coverage to this region will further enhance the performance of CMS. Following an extensive R&D program, CMS has identified triple-foil gas electron multiplier (GEM) detectors as a solution for the first muon station in the region 1.6<|η|<2.2, while continuing R&D is ongoing for additional regions.
DOI: 10.1088/1748-0221/15/05/p05023
2020
Cited 4 times
Detector Control System for the GE1/1 slice test
Gas Electron Multiplier (GEM) technology, in particular triple-GEM, was selected for the upgrade of the CMS endcap muon system following several years of intense effort on R&D. The triple-GEM chambers (GE1/1) are being installed at station 1 during the second long shutdown with the goal of reducing the Level-1 muon trigger rate and improving the tracking performance in the harsh radiation environment foreseen in the future LHC operation [1]. A first installation of a demonstrator system started at the beginning of 2017: 10 triple-GEM detectors were installed in the CMS muon system with the aim of gaining operational experience and demonstrating the integration of the GE1/1 system into the trigger. In this context, a dedicated Detector Control System (DCS) has been developed, to control and monitor the detectors installed and integrating them into the CMS operation. This paper presents the slice test DCS, describing in detail the different parts of the system and their implementation.
DOI: 10.1088/1748-0221/15/10/p10013
2020
Cited 4 times
Triple-GEM discharge probability studies at CHARM: simulations and experimental results
The CMS muon system in the region with 2.03<|η|<2.82 is characterized by a very harsh radiation environment which can generate hit rates up to 144 kHz/cm2 and an integrated charge of 8 C/cm2 over ten years of operation. In order to increase the detector performance and acceptance for physics events including muons, a new muon station (ME0) has been proposed for installation in that region. The technology proposed is Triple—Gas Electron Multiplier (Triple-GEM), which has already been qualified for the operation in the CMS muon system. However, an additional set of studies focused on the discharge probability is necessary for the ME0 station, because of the large radiation environment mentioned above. A test was carried out in 2017 at the Cern High energy AcceleRator Mixed (CHARM) facility, with the aim of giving an estimation of the discharge probability of Triple-GEM detectors in a very intense radiation field environment, similar to the one of the CMS muon system. A dedicated standalone Geant4 simulation was performed simultaneously, to evaluate the behavior expected in the detector exposed to the CHARM field. The geometry of the detector has been carefully reproduced, as well as the background field present in the facility. This paper presents the results obtained from the Geant4 simulation, in terms of sensitivity of the detector to the CHARM environment, together with the analysis of the energy deposited in the gaps and of the processes developed inside the detector. The discharge probability test performed at CHARM will be presented, with a complete discussion of the results obtained, which turn out to be consistent with measurements performed by other groups.
DOI: 10.1016/j.nima.2006.04.046
2006
Cited 6 times
Fine synchronization of the CMS muon drift tubes local trigger
The drift tubes based CMS barrel muon trigger, which uses self-triggering arrays of drift tubes, is able to perform the identification of the muon parent bunch crossing using a rather sophisticated algorithm. The identification is unique only if the trigger chain is correctly synchronized. Some beam test time was devoted to take data useful to investigate the synchronization of the trigger electronics with the machine clock. Possible alternatives were verified and the dependence on muon track properties was studied.
DOI: 10.1088/1748-0221/4/05/p05002
2009
Cited 4 times
Offline calibration procedure of the CMS Drift Tube detectors
The barrel region of the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider is instrumented with Drift Tube (DT) detectors. This paper describes in full details the calibration of the DT hit reconstruction algorithm. After inter-channel synchronization has been verified through the appropriate hardware procedure, the time pedestals are extracted directly from the distribution of the recorded times. Further corrections for time-of-flight and time of signal propagation are applied as soon as the three-dimensional hit position within the DT chamber is known. The different effects of the time pedestal miscalibration on the two main hit reconstruction algorithms are shown. The drift velocity calibration algorithm is based on the meantimer technique. Different meantimer relations for different track angles and patterns of hit cells are used. This algorithm can also be used to determine the uncertainty on the reconstructed hit position.
DOI: 10.1109/nssmic.2014.7431249
2014
Cited 3 times
Performance of a large-area GEM detector prototype for the upgrade of the CMS muon endcap system
Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the 1.5 <| η |< 2.2 region of the muon endcap mainly to control muon level-1 trigger rates after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by 3,072 radial strips with 455 µrad pitch arranged in eight η-sectors. We assembled a full-size GE1/1 prototype of 1m length at Florida Tech and tested it in 20–120 GeV hadron beams at Fermilab using Ar/CO2 70∶30 and the RD51 scalable readout system. Four small GEM detectors with 2-D readout and an average measured azimuthal resolution of 36 µrad provided precise reference tracks. Construction of this largest GEM detector built to-date is described. Strip cluster parameters, detection efficiency, and spatial resolution are studied with position and high voltage scans. The plateau detection efficiency is [97.1 ± 0.2 (stat)]%. The azimuthal resolution is found to be [123.5 ± 1.6 (stat)] µrad when operating in the center of the efficiency plateau and using full pulse height information. The resolution can be slightly improved by ∼ 10 µrad when correcting for the bias due to discrete readout strips. The CMS upgrade design calls for readout electronics with binary hit output. When strip clusters are formed correspondingly without charge-weighting and with fixed hit thresholds, a position resolution of [136.8 ± 2.5 stat] µrad is measured, consistent with the expected resolution of strip-pitch/equation µrad. Other η-sectors of the detector show similar response and performance.
DOI: 10.1088/1748-0221/9/03/c03052
2014
Cited 3 times
Development of the data acquisition system for the Triple-GEM detectors for the upgrade of the CMS forward muon spectrometer
In this contribution we will report on the progress of the design of the readout and data acquisition system being developed for triple-GEM detectors which will be installed in the forward region (1.5 < |η| < 2.2) of the CMS muon spectrometer during the 2nd long shutdown of the LHC, expected in the period 2017–2018. The system will be designed to take full advantage of current generic developments introduced for the LHC upgrades. The current design is based on the use of CERN GLIB boards hosted in micro-TCA crates for the off-detector electronics and the Versatile Link with the GBT chipset to link the front-end electronics to the GLIB boards. In this contribution we will describe the physics goals, the hardware architectures and report on the expected performance of the CMS GEM readout system, including preliminary timing resolution simulations.
DOI: 10.1109/tns.2018.2871428
2018
Cited 3 times
Operational Experience With the GEM Detector Assembly Lines for the CMS Forward Muon Upgrade
The CMS Collaboration has been developing large-area triple-gas electron multiplier (GEM) detectors to be installed in the muon Endcap regions of the CMS experiment in 2019 to maintain forward muon trigger and tracking performance at the High-Luminosity upgrade of the Large Hadron Collider (LHC); 10 preproduction detectors were built at CERN to commission the first assembly line and the quality controls (QCs). These were installed in the CMS detector in early 2017 and participated in the 2017 LHC run. The collaboration has prepared several additional assembly and QC lines for distributed mass production of 160 GEM detectors at various sites worldwide. In 2017, these additional production sites have optimized construction techniques and QC procedures and validated them against common specifications by constructing additional preproduction detectors. Using the specific experience from one production site as an example, we discuss how the QCs make use of independent hardware and trained personnel to ensure fast and reliable production. Preliminary results on the construction status of CMS GEM detectors are presented with details of the assembly sites involvement.
DOI: 10.1088/1748-0221/14/12/c12010
2019
Cited 3 times
Study of the effects of radiation on the CMS Drift Tubes Muon Detector for the HL-LHC
The CMS drift tubes (DT) muon detector, built for withstanding the LHC expected integrated and instantaneous luminosities, will be used also in the High Luminosity LHC (HL-LHC) at a 5 times larger instantaneous luminosity and, consequently, much higher levels of radiation, reaching about 10 times the LHC integrated luminosity. Initial irradiation tests of a spare DT chamber at the CERN gamma irradiation facility (GIF++), at large (∼ O(100)) acceleration factor, showed ageing effects resulting in a degradation of the DT cell performance. However, full CMS simulations have shown almost no impact in the muon reconstruction efficiency over the full barrel acceptance and for the full integrated luminosity. A second spare DT chamber was moved inside the GIF++ bunker in October 2017. The chamber was being irradiated at lower acceleration factors, and only 2 out of the 12 layers of the chamber were switched at working voltage when the radioactive source was active, being the other layers in standby. In this way the other non-aged layers are used as reference and as a precise and unbiased telescope of muon tracks for the efficiency computation of the aged layers of the chamber, when set at working voltage for measurements. An integrated dose equivalent to two times the expected integrated luminosity of the HL-LHC run has been absorbed by this second spare DT chamber and the final impact on the muon reconstruction efficiency is under study. Direct inspection of some extracted aged anode wires presented a melted resistive deposition of materials. Investigation on the outgassing of cell materials and of the gas components used at the GIF++ are underway. Strategies to mitigate the ageing effects are also being developed. From the long irradiation measurements of the second spare DT chamber, the effects of radiation in the performance of the DTs expected during the HL-LHC run will be presented.
DOI: 10.1016/j.nima.2016.01.059
2016
Fiber Bragg Grating (FBG) sensors as flatness and mechanical stretching sensors
A novel approach which uses Fiber Bragg Grating (FBG) sensors has been utilized to assess and monitor the flatness of Gaseous Electron Multipliers (GEM) foils. The setup layout and preliminary results are presented.
DOI: 10.1109/nssmic.2015.7581797
2015
Charged particle detection performance of Gas Electron Multiplier (GEM) detectors for the upgrade of CMS endcap muon system at the CERN LHC
The Compact Muon Solenoid (CMS) detector is one of the two general-purpose detectors at the CERN LHC. LHC will provide exceptional high instantaneous and integrated luminosity after second long shutdown. The forward region |η| ≥ 1:5 of CMS detector will face extremely high particle rates in tens of kHz/cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> and hence it will affect the momentum resolution, efficiency and longevity of the muon detectors. Here, η is pseudorapidity defined as η = −ln(tan(θ/2)), where θ is the polar angle measured from z-axis. To overcome these issues the CMSGEM collaboration has proposed to install new large size rate capable Triple Gas Electron Multiplier (GEM) detectors in the forward region of CMS muon system. The first set of Triple GEM detectors will be installed in the GE1/1 region (1:6 < |η| < 2.2) of the muon endcap during the long shutdown 2 (LS2) of the LHC. Towards this goal, full size CMS Triple GEM detectors have been fabricated and tested at the CERN SPS, H2 and H4 test beam facility. The GEM detectors were operated with two gas mixtures: Ar/CO <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> (70/30) and Ar/CO <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> /CF <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">4</inf> (45/15/40). In 2014, good quality data was collected during test beam campaigns. In this paper, the performance of the detectors is summarized based on their tracking efficiency and time resolution.
DOI: 10.1016/s0168-9002(96)01098-4
1997
Cited 8 times
A new vertex detector made of glass capillaries
We have developed a new detector technique that allows high quality imaging of ionizing particle tracks with very high spatial and time resolution.Central to this technique are liquid-core fibres of about 20 pm diameter read out by an optoelectronic system including a CCD.The fibres act simultaneously as target, detector and light guides.A large-volume prototype, consisting of 5 X IO5 capillaries of 20 pm diameter and 180 cm length, has been tested in the CERN wide-band neutrino beam.A sample of high-multiplicity neutrino interactions was recorded, demonstrating the imaging quality of this detector.First results from the reconstruction of these events are reported.A track residual of 28 pm and a vertex resolution of 30 pm has been achieved.Future applications of capillary detectors for neutrino and beauty physics are being investigated within the framework of the RD46 collaboration.
DOI: 10.1016/0168-9002(95)00638-9
1995
Cited 8 times
Experimental results from a large volume active target made of glass capillaries and liquid scintillator
We are investigating the feasibility of high-resolution tracking with an active target made of glass capillaries filled with organic liquid scintillator. This technique allows real time detection of short-lived particle decays. In this paper, we report on experimental results obtained from an active target having 2 × 2 cm2 cross section and 180 cm length, installed in front of the CHORUS detector and exposed to the CERN Wide Band Neutrino Beam. The detector consists of 5.1 × 105 capillaries with 20 μm inner diameter, read out by a single optoelectronic chain and a Megapixel CCD. Details on tests in the neutrino beam will be reported. First neutrino interactions have been detected.
DOI: 10.1016/j.nima.2023.168723
2023
Production and validation of industrially produced large-sized GEM foils for the Phase-2 upgrade of the CMS muon spectrometer
The upgrade of the CMS detector for the high luminosity LHC (HL-LHC) will include gas electron multiplier (GEM) detectors in the end-cap muon spectrometer. Due to the limited supply of large area GEM detectors, the Korean CMS (KCMS) collaboration had formed a consortium with Mecaro Co., Ltd. to serve as a supplier of GEM foils with area of approximately 0.6 m2. The consortium has developed a double-mask etching technique for production of these large-sized GEM foils. This article describes the production, quality control, and quality assessment (QA/QC) procedures and the mass production status for the GEM foils. Validation procedures indicate that the structure of the Korean foils are in the designed range. Detectors employing the Korean foils satisfy the requirements of the HL-LHC in terms of the effective gain, response uniformity, rate capability, discharge probability, and hardness against discharges. No aging phenomena were observed with a charge collection of 82 mC cm−2. Mass production of KCMS GEM foils is currently in progress.
DOI: 10.1088/1748-0221/18/11/p11029
2023
Impact of magnetic field on the stability of the CMS GE1/1 GEM detector operation
Abstract The Gas Electron Multiplier (GEM) detectors of the GE1/1 station of the CMS experiment have been operated in the CMS magnetic field for the first time on the 7 th of October 2021. During the magnetic field ramps, several discharge phenomena were observed, leading to instability in the GEM High Voltage (HV) power system. In order to reproduce the behavior, it was decided to conduct a dedicated test at the CERN North Area with the Goliath magnet, using four GE1/1 spare chambers. The test consisted in studying the characteristics of discharge events that occurred in different detector configurations and external conditions. Multiple magnetic field ramps were performed in sequence: patterns in the evolution of the discharge rates were observed with these data. The goal of this test is the understanding of the experimental conditions inducing discharges and short circuits in a GEM foil. The results of this test lead to the development of procedure for the optimal operation and performance of GEM detectors in the CMS experiment during the magnet ramps. Another important result is the estimation of the probability of short circuit generation, at 68 % confidence level, p short HV OFF = 0.42 -0.35 +0.94 % with detector HV OFF and p short HV OFF &lt; 0.49% with the HV ON. These numbers are specific for the detectors used during this test, but they provide a first quantitative indication on the phenomenon, and a point of comparison for future studies adopting the same procedure.
2000
Cited 5 times
MONOLITH: A massive magnetized iron detector for neutrino oscillation studies
DOI: 10.1088/1748-0221/12/02/p02003
2017
The Triple GEM Detector Control System for CMS forward muon spectrometer upgrade
The CMS experiment at LHC will upgrade its forward muon spectrometer by incorporating Triple-GEM detectors. This upgrade referred to as GEM Endcap (GE1/1), consists of adding two back-to-back Triple-GEM detectors in front of the existing Cathode Strip Chambers (CSC) in the innermost ring of the endcap muon spectrometer. Before the full installation of 144 detectors in 2019–2020, CMS will first install ten single chamber prototypes during the early 2017. This pre-installation is referred as the slice test. These ten detectors will be read-out by VFAT2 chips [1]. On-detector there is also a FPGA mezzanine card which sends VFAT2 data optically to the μTCA back-end electronics. The correct and safe operation of the GEM system requires a sophisticated and powerful online Detector Control System, able to monitor and control many heterogeneous hardware devices. The DCS system developed for the slice test has been tested with CMS Triple-GEM detectors in the laboratory. In this paper we describe the newly developed DCS system and present the first results obtained in the GEM assembly and quality assurance laboratory.
DOI: 10.1051/epjconf/201817403002
2018
A novel application of Fiber Bragg Grating (FBG) sensors in MPGD
We present a novel application of Fiber Bragg Grating (FBG) sensors in the construction and characterisation of Micro Pattern Gaseous Detector (MPGD), with particular attention to the realisation of the largest triple (Gas electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of about 0.5 m 2 active area each, employing three GEM foils per chamber, to be installed in the forward region of the CMS endcap during the long shutdown of LHC in 2108-2019. The large active area of each GE1/1 chamber consists of GEM foils that are mechanically stretched in order to secure their flatness and the consequent uniform performance of the GE1/1 chamber across its whole active surface. So far FBGs have been used in high energy physics mainly as high precision positioning and re-positioning sensors and as low cost, easy to mount, low space consuming temperature sensors. FBGs are also commonly used for very precise strain measurements in material studies. In this work we present a novel use of FBGs as flatness and mechanical tensioning sensors applied to the wide GEM foils of the GE1/1 chambers. A network of FBG sensors have been used to determine the optimal mechanical tension applied and to characterise the mechanical tension that should be applied to the foils. We discuss the results of the test done on a full-sized GE1/1 final prototype, the studies done to fully characterise the GEM material, how this information was used to define a standard assembly procedure and possible future developments.
DOI: 10.1088/1748-0221/16/10/p10032
2021
Impact of the hole orientation of asymmetric GEM foils on the performance of single and triple GEM detectors
The Gas Electron Multiplier (GEM) foil is an amplification stage that has been introduced to overcome the problem of discharges observed in gaseous detectors. There are two major production techniques of GEM foils: double-mask and single-mask etching. Despite being an effective method, an asymmetry is observed between the top and bottom diameters of GEM holes in single mask technique compared to double mask one. In this paper we describe extensive simulations and measurements to study this hole asymmetry and its effect on the performance of GEM based detectors. The experimental data is collected using GEM foils of various hole geometries and orientations. In simulations, the same dimensions are used to study the properties of the detector. Simulations are performed with the Garfield++ simulation package along with ANSYS for creating the geometry of the GEM foils as well as the triple-GEM detector and the meshing needed for the field calculations. The simulation results match the observations from experimental studies. The gains measured with single and triple-GEM detectors are lower if asymmetric foils are oriented with the smaller diameters towards the readout plane. Detailed simulation of the amplification and collection steps indicates that the lower gain is attributed to a loss of electrons at the GEM3 foil for the first time.
DOI: 10.1016/j.nima.2015.11.125
2016
Status report of the upgrade of the CMS muon system with Triple-GEM detectors
For the High Luminosity LHC CMS is planning to install new large size Triple-GEM detectors, equipped with a new readout system in the forward region of its muon system (1.5<|η|<2.2). In this note we report on the status of the project, the main achievements regarding the detectors as well as the electronics and readout system.
DOI: 10.1007/978-3-319-15001-7_11
2015
Searches for Physics Beyond the Standard Model
DOI: 10.1051/epjconf/20159503016
2015
CMS upgrade and future plans
CMS plans for operation at the LHC phase-II unprecedented in terms of luminosity thus resulting in serious consequences for detector performance. To achieve the goal to maintain the present excellent performance of the CMS detector, several upgrades are necessary. To handle the high phase-II data rates, the readout and trigger systems are redesigned using recent technology developments. The high particle rates will accelerate detector aging and require replacement of the tracker and forward calorimeters. In addition, the muon system will be extended.
2014
Impact of the Radiation Background on the CMS muon high-eta upgrade for the LHC high luminosity scenario
The Compact Muon Solenoid (CMS) experiment at the LHC is planning an upgrade of its muon detection system aiming to extend the muon detection capabilities in the forward region with the installation of new muon stations based on Gas Electron Multiplier (GEM) and Resistive Plate Chambers (RPC) technologies during the so-called Phase-2 upgrade scenario. With the imminent increase on luminosity to 5 × 1034cm-2s-1 and center of mass collision energy of 14 TeV an unprecedented and hostile radiation environment will be created, the most affected detectors will be the ones located in the forward region where the intense flux of neutrons and photons could potentially degrade the detector performance. Using FLUKA simulation the expected radiation environment is estimated for the regions of interest, possible shielding scenarios are proposed and the effect on the detector performance is discussed.
DOI: 10.48550/arxiv.1412.0228
2014
Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System
Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \mid\eta\mid < 2.2$ region of the muon endcap mainly to control muon level-1 trigger rates after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by 3,072 radial strips with 455 $\mu$rad pitch arranged in eight $\eta$-sectors. We assembled a full-size GE1/1 prototype of 1m length at Florida Tech and tested it in 20-120 GeV hadron beams at Fermilab using Ar/CO$_{2}$ 70:30 and the RD51 scalable readout system. Four small GEM detectors with 2-D readout and an average measured azimuthal resolution of 36 $\mu$rad provided precise reference tracks. Construction of this largest GEM detector built to-date is described. Strip cluster parameters, detection efficiency, and spatial resolution are studied with position and high voltage scans. The plateau detection efficiency is [97.1 $\pm$ 0.2 (stat)]\%. The azimuthal resolution is found to be [123.5 $\pm$ 1.6 (stat)] $\mu$rad when operating in the center of the efficiency plateau and using full pulse height information. The resolution can be slightly improved by $\sim$ 10 $\mu$rad when correcting for the bias due to discrete readout strips. The CMS upgrade design calls for readout electronics with binary hit output. When strip clusters are formed correspondingly without charge-weighting and with fixed hit thresholds, a position resolution of [136.8 $\pm$ 2.5 stat] $\mu$rad is measured, consistent with the expected resolution of strip-pitch/$\sqrt{12}$ = 131.3 $\mu$rad. Other $\eta$-sectors of the detector show similar response and performance.
DOI: 10.1016/s0168-9002(01)01292-x
2001
Cited 3 times
Neutrino tracking calorimetry with plastic scintillator bars
Abstract The technique of plastic scintillator bars coupled to wavelength shifting fibers is proposed for neutrino tracking calorimeters, in the context of very large, massive detectors for experiments on the neutrino factory beam. A prototype has been built with 180 scintillator bars interleaved with an equal number of iron bars. The light from the fibers is collected by multi-anode PMTs and converted with Amplitude–Time–Pattern self-triggering digitizing electronics. The prototype has been tested with electron and pion beams at CERN.
DOI: 10.1016/j.nima.2008.08.100
2009
The CMS muon barrel drift tubes system commissioning
The CMS muon barrel drift tubes system has been recently fully installed and commissioned in the experiment. The performance and the current status of the detector are briefly presented and discussed.
DOI: 10.1051/epjconf/201817403003
2018
Quality control for the first large areas of triple-GEM chambers for the CMS endcaps
The CMS Collaboration plans to equip the very forward muon system with triple-GEM detectors that can withstand the environment of the High-Luminosity LHC. This project is at the final stages of R&amp;D and moving to production. An unprecedented large area of several 100 m 2 are to be instrumented with GEM detectors which will be produced in six different sites around the world. A common construction and quality control procedure is required to ensure the performance of each detector. The quality control steps will include optical inspection, cleaning and baking of all materials and parts used to build the detector, leakage current tests of the GEM foils, high voltage tests, gas leak tests of the chambers and monitoring pressure drop vs. time, gain calibration to know the optimal operation region of the detector, gain uniformity tests, and studying the efficiency, noise and tracking performance of the detectors in a cosmic stand using scintillators.
DOI: 10.1016/j.radphyschem.2020.108747
2020
Irradiation aging of the CMS Drift Tube muon detector
During the High Luminosity LHC, the Drift Tube chambers installed in the CMS detector need to operate with an integrated dose ten times higher than expected at the LHC due to the increase in integrated luminosity from 300 fb-1 to 3000 fb-1. Irradiations have been performed to assess the performance of the detector under such conditions and to characterize the radiation aging of the detector. The presented analysis focuses on the behaviour of the high voltage currents and the dose measurements needed to extrapolate the results to High Luminosity conditions, using data from the photon irradiation campaign at GIF++ in 2016 as well as the efficiency analysis from the irradiation campaign started in 2017. Although the single-wire loss of high voltage gain observed of 70% is very high, the muon reconstruction efficiency is expected to decrease less than 20% during the full duration of High Luminosity LHC in the areas under highest irradiation.
DOI: 10.1088/1748-0221/15/06/c06004
2020
Influence of hole geometry on gas gain in GEM detectors
Gas electron multipliers (GEMs) belong to the most modern and advanced technologies in the field of gaseous detectors. Detectors, based on the GEM technology, enjoy great popularity in various fields of physics. Especially in the field of high-energy physics, GEMs are well-appreciated thanks to their flexibility in geometry, resistance to aging and excellent performance in high-rate environments. The core of the detector consists of thin foils with an etched pattern of holes. The detection principle relies on electron multiplication inside the holes, where a high electric field is present. New etching techniques have been used for the production of large-size (0.3 m2 - 0.4 m2) GEM foils needed for high-energy physics experiments. The new techniques result in different hole geometries. To better understand the gas gain dependence on the hole geometry, several measurements have been performed with a triple-GEM detector, and have been complemented by GARFIELD++ simulations. The results are compared with other recent studies.
DOI: 10.1088/1742-6596/1561/1/012006
2020
Two years’ test of a temperature sensing system based on fibre Bragg grating technology for the CMS GE1/1 detectors
Abstract A temperature monitoring system based on fibre Bragg grating (FBG) fibre optic sensors has been developed for the gas electron multiplier (GEM) chambers of the Compact Muon Solenoid (CMS) detector. The monitoring system was tested in prototype chambers undergoing a general test of the various technological solutions adopted for their construction. The test lasted about two years and was conducted with the chambers being installed in the CMS detector and operated during regular experimental running. In this paper, we present test results that address the choice of materials and procedures for the production and installation of the FBG temperature monitoring system in the final GEM chambers.
DOI: 10.1088/1748-0221/15/12/p12019
2020
Interstrip capacitances of the readout board used in large triple-GEM detectors for the CMS Muon Upgrade
We present analytical calculations, Finite Element Analysis modelling, and physical measurements of the interstrip capacitances for different potential strip geometries and dimensions of the readout boards for the GE2/1 triple-Gas Electron Multiplier detector in the CMS muon system upgrade. The main goal of the study is to find configurations that minimize the interstrip capacitances and consequently maximize the signal-to-noise ratio for the detector. We find agreement at the 1.5–4.8% level between the two methods of calculations and on the average at the 17% level between calculations and measurements. A configuration with halved strip lengths and doubled strip widths results in a measured 27–29% reduction over the original configuration while leaving the total number of strips unchanged. We have now adopted this design modification for all eight module types of the GE2/1 detector and will produce the final detector with this new strip design.
DOI: 10.1016/s0920-5632(97)00097-2
1997
Cited 3 times
Capillary detectors for high resolution tracking
We present a new tracking device based on glass capillary bundles or layers filled with highly purified liquid scintillator and read out at one end by means of image intensifiers and CCD devices. A large-volume prototype consisting of 5 × 105 capillaries with a diameter of 20 μm and a length of 180 cm and read out by a megapixel CCD has been tested with muon and neutrino beams at CERN. With this prototype a two track resolution of 33 μm was achieved with passing through muons. Images of neutrino interactions in a capillary bundle have also been acquired and analysed. Read-out chains based on Electron Bombarded CCD (EBCCD) and image pipeline devices are also investigated. Preliminary results obtained with a capillary bundle read out by an EBCCD are presented.
DOI: 10.1016/s0168-9002(98)01084-5
1998
Cited 3 times
Reconstruction of neutrino interactions observed in a liquid-core fibre detector
DOI: 10.1016/s0920-5632(00)00663-0
2000
Searching for atmospheric neutrino oscillations with a massive magnetized iron detector
Abstract We describe a project to further investigate the phenomenon of neutrino oscillation using atmospheric neutrinos. The novel feature of a magnetic field allows to clearly detect the first oscillation minimum and measure the oscillation parameters.
DOI: 10.1016/s0168-9002(00)01231-6
2001
Plastic scintillator bar with WLS fiber calorimeter for neutrino physics
Abstract A calorimeter with 180 plastic scintillator bars interleaved with 180 iron bars has been built and tested with pion and electron beams at CERN. The plastic scintillator bars, coupled to wavelength shifting fibers, are read with multi-anode PMTs and Amplitude-Time-Pattern self-triggering digitizing electronics. This type of calorimeter could be well suited for the construction of large, many kton detectors for neutrino oscillation experiments on the CERN to Gran Sasso CNGS beam or for the neutrino factory.
DOI: 10.1063/1.2220464
2006
Physics With CMS — Potential And Challenges
The CMS muon system is an important subdetector to trigger on and select rare interesting physics events from the large background at the LHC, and to allow kinematic muon reconstruction based on precise momentum measurements. Three detection technologies, all within the magnetized return yoke, identify muons and determine their charge and momentum. The overview outlines the requirements for the muon system, shows their implementation and summarizes the detector performance.
DOI: 10.1393/ncc/i2016-16260-7
2015
Impact of the GE1/1 upgrade on CMS muon system performance
During the future LHC upgrade planned in 2018, the forward endcap region of the CMS muon spectrometer will be upgraded with GEM chambers. GEM technology is able to withstand the radiation environment expected in the forward region. The GE1/1 station will be included in the muon L1 trigger, allowing to keep low p(T) threshold even at high luminosity. Moreover, it will bring detection redundancy in the most critical part of the CMS muon system, along with benefits to muon reconstruction performance.
DOI: 10.1393/ncc/i2016-16269-x
2016
Development and performance of Triple-GEM detectors for the upgrade of the muon system of the CMS experiment
The CMS Collaboration is evaluating GEM detectors for the upgrade of the muon system. This contribution will focus on the R&D performed on cham design features and will discuss the performance of the upgraded detector.
DOI: 10.1142/9789814603164_0083
2014
Upgrade of the muon system in the high eta region of the CMS experiment at LHC with GEMs
DOI: 10.1109/nssmic.2015.7581803
2015
CMS muon system phase 2 upgrade with triple-GEM detectors
The Compact Muon Solenoid (CMS) detector installed at the CERN Large Hadron Collider (LHC) has an extensive muon system which provides information simultaneously for identification, track reconstruction and triggering of muons. As a consequence of the extreme particle rate and high integrated charge, the essentiality to upgrade the LHC has given rise to the High Luminosity phase of the LHC (HL-LHC) project so that the CMS muon system will be upgraded with superior technological challenges. The CMS GEM collaboration offers a solution to equip the high-eta region of the muon system for Phase 2 (after the year 2017) with large-area triple-layer Gas Electron Multiplier (GEM) detectors, since GEMs have the ability to provide robust and redundant tracking and triggering functions with an excellent spatial resolution of order 100 micron and a high particle rate capability, with a close to 100% detection efficiency. In this contribution, the present status of the triple-GEM project will be reviewed, and the significant achievements from the start of the R&D in 2009 will be emphasized.
DOI: 10.1109/nssmic.2014.7431236
2014
Status report on the CMS forward muon upgrade with large-size triple-GEM detectors
For the High-Luminosity LHC (HL-LHC) phase the CMS GEM Collaboration is planning to install new large-size (990×220–455mm2) triple-GEM detectors, equipped with a new readout system, in the forward region of the muon system (1.5< |η| <2.2) of the CMS detector. Combining triggering and tracking functionalities the new triple-foil Gas Electron Multiplier (GEM) chambers will improve both the performance of the CMS muon trigger and the muon reconstruction/identification in CMS experiment. The addition of triple-GEM chambers to the forward region of the CMS muon system will add a necessary layer of redundancy. Starting from 2009 the CMS GEM Collaboration has built several small and full-size prototypes with different geometries, keeping improving the assembly techniques. All these prototypes have been tested in laboratories as well as with beam tests at the CERN Super Proton Synchrotron (SPS) and at Fermi National Accelerator Laboratory. In this contribution we will report on the status of the CMS upgrade project with triple-GEM chambers and its impact on the CMS performance as well as the hardware architectures and expected capability of the CMS GEM readout system.
DOI: 10.22323/1.213.0065
2015
The Triple-GEM Project for the Phase 2 Upgrade of the CMS Muon System
In view of the high-luminosity phase of the LHC, the CMS Collaboration is considering the use of Gas Electron Multiplier (GEM) detector technology for the upgrade of its muon system in the forward region. With their ability to handle the extreme particle rates expected in that area, such micro-pattern gas detectors can sustain a high performance and redundant muon trigger system. At the same time, with their excellent spatial resolution, they can improve the muon track reconstruction and identification capabilities of the forward detector, effectively combining tracking and triggering functions in one single device. The present status of the CMS GEM project will be reviewed, highlighting importants steps and achievements since the start of the R&D activities in 2009. The baseline design of the triple-GEM detectors proposed for installation in different stations of the CMS muon endcap system will be described, along with the associated frontend electronics and data-acquisition system. The expected impact on the performance of the CMS muon system will be discussed, and results from detector tests, both in the lab and in test beams will be presented.
DOI: 10.22323/1.180.0284
2014
Searches for dark matter at CMS
On behalf of the CMS collaborationDark matter particles may be produced in pp-collisions at the LHC with their interaction with standard model particles being described by an effective field theory.The pair-produced dark matter cannot be detected directly but rather through radiation of a single jet/photon or the observation of a recoiling W-or Z-boson.The CMS collaboration has performed searches for dark matter using 20 fb -1 of pp collision events at sqrt(s)= 8TeV with a single jet and single lepton in the final state.The search strategy and results are described in this paper.
DOI: 10.48550/arxiv.1512.08529
2015
A novel application of Fiber Bragg Grating (FBG) sensors in MPGD
We present a novel application of Fiber Bragg Grating (FBG) sensors in the construction and characterisation of Micro Pattern Gaseous Detector (MPGD), with particular attention to the realisation of the largest triple (Gas electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of about 0.5 m2 active area each, employing three GEM foils per chamber, to be installed in the forward region of the CMS endcap during the long shutdown of LHC in 2108-2019. The large active area of each GE1/1 chamber consists of GEM foils that are mechanically stretched in order to secure their flatness and the consequent uniform performance of the GE1/1 chamber across its whole active surface. So far FBGs have been used in high energy physics mainly as high precision positioning and re-positioning sensors and as low cost, easy to mount, low space consuming temperature sensors. FBGs are also commonly used for very precise strain measurements in material studies. In this work we present a novel use of FBGs as flatness and mechanical tensioning sensors applied to the wide GEM foils of the GE1/1 chambers. A network of FBG sensors have been used to determine the optimal mechanical tension applied and to characterise the mechanical tension that should be applied to the foils. We discuss the results of the test done on a full-sized GE1/1 final prototype, the studies done to fully characterise the GEM material, how this information was used to define a standard assembly procedure and possible future developments.
DOI: 10.22323/1.234.0225
2016
Physics motivations and expected performance of the CMS muon system upgrade with triple-GEM detectors
For the LHC High Luminosity phase (HL-LHC) the CMS GEM Collaboration is planning to install new large size triple-GEM detectors in the forward region of the muon system (1.5<|η|<2.2) of the CMS detector.The muon reconstruction with triple-GEM chambers information included have been successfully integrated in the official CMS software, allowing physics studies to be carried out.The new sub-detector will be able to cope the extreme particle rates expected in this region along with a high spatial resolution.The resulting benefit in terms of triggering and tracking capabilities has been studied: the expected improvement in the performance of the muon identification and track reconstruction as well as the expected improvement coming from the lowering of the muon p T trigger tresholds will be presented.The contribution will review the status of the CMS upgrade project with the usage of GEM detector, discussing the trigger, the muon reconstruction performance and the impact on the physics analyses.
DOI: 10.1051/epjconf/20149503016
2015
CMS upgrade and future plans
CMS plans for operation at the LHC phase-II unprecedented in terms of luminosity thus resulting in serious consequences for detector performance. To achieve the goal to maintain the present excellent performance of the CMS detector, several upgrades are necessary. To handle the high phase-II data rates, the readout and trigger systems are redesigned using recent technology developments. The high particle rates will accelerate detector aging and require replacement of the tracker and forward calorimeters. In addition, the muon system will be extended.
DOI: 10.1016/s0168-9002(00)01301-2
2001
Efficient detection of single photons – a comparative study on multi-anode PM and HPD
We have performed comparative light yield measurements of Hamamatsu multi-channel PMTs and HPDs from HPD. Analysing the observed spectra with the standard method leads to an underestimation of the number of photons, mainly due to backscattering. Subsequently we developed a new formula where this effect is taken into account.
DOI: 10.1002/9783527634965.ch16
2011
Muon Detectors: Catching Penetrating Particles
This chapter contains sections titled: Sources of Muons Energy Loss of Muons and Muon Identification Measurement of Muon Momenta Muon Identification in ATLAS and CMS ATLAS and CMS Muon Chambers Muon Track Reconstruction and Identification References
DOI: 10.48550/arxiv.1211.1494
2012
A GEM Detector System for an Upgrade of the High-eta Muon Endcap Stations GE1/1 + ME1/1 in CMS
Based on the CMS Upgrade R&amp;D Proposal RD10.02, we describe the motivation and main features of the CMS GEM Project for LS2 and propose the addition of a full GE1/12 detector station comprising Gas Electron Multiplier (GEM) chambers to the forward muon system of CMS. The limitations of the currently existing forward muon detector when operating at increasingly high luminosity expected after LS1 are laid out followed by a brief description of the anticipated performance improvements achievable with a GE1/1 station. The second part describes the detector system followed by an overview of electronics and associated services including a discussion of the schedule and cost of the project. Plans for a precursor demonstrator installation in LS1 are presented. This proposal is intended as a concise follow-up of the detailed document CMS-IN-2012-023. If approved, this is to be followed by a detailed Technical Design Report.
DOI: 10.22323/1.174.0178
2013
Search for compositeness and contact interactions in CMS
2012
Search for compositeness and contact interactions in CMS
DOI: 10.1016/0168-9002(94)01720-4
1995
Status report on CHORUS experiment at CERN
The WA95/CHORUS experiment at CERN is a dedicated vμ−vτ oscillation search experiment. Using the wide band neutrino beam of the CERN-SPS accelerator, with an exposure of 2.4 × 1019 protons on the target, this experiment will explore the domain of small mixing angles down to sin22θμτ ≈ 3 × 10−4 for mass differences Δm2 > 1 eV2, more than one order of magnitude better than the current limits. The conceptual design of the CHORUS experiment and data on the detector performances are reported.
DOI: 10.1117/12.218649
1995
Charged-particle tracking with high spatial and temporal resolution using capillary arrays filled with liquid scintillator
We abstract developed a new technique that allows the trajectories of ionizing particles to be imaged with very high spatial and temporal resolution. This technique, developed for future experiments in high-energy physics, may also be applied in other field. Central to the technique is a detector consisting of a bundle of thin, glass capillaries filled with a liquid scintillator of high refractive index. These liquid-core scintillating fibers act simultaneously as a detector of charged particles and as an image guide. Track images seen at the readout end of the capillary bundle are amplified by an optoelectronic chain consisting of a set of image- intensifier tubes and read by a photosensitive CCD camera. We report here on results obtained with detector prototypes. A spatial resolution of 6-14 micrometers , dependent on image magnification prior to readout, has been obtained with 16 micrometers capillaries. The high scintillation efficiency of the liquid scintillator used and a large light attenuation length-- approximately 3 m for 20 micrometers capillaries--result in hit densities along the track of a minimum-ionizing particle of 8.5 mm<sup>-1</sup> and 3.5 mm<sup>-1</sup> at distances from the readout window of approximately 2 cm and approximately 1 m respectively. The radiation resistance of the detector is an order of magnitude greater than that of other types of tracking device of comparable performance. To complement the detector we have been developing a new readout system based around a gateable vacuum image pipeline (VIP) and an electron- bombarded CCD camera. These increase the spatial and temporal resolution obtained with detector and render it particlarly attractive as a microvertex detector for the observation of short-lived particles in high-energy physics experiments performed with evelated interaction rates.
DOI: 10.1016/s0168-9002(99)00883-9
2000
Application of liquid-core fibres for a radiation-hard vertex detector
We propose a novel vertex detector based on liquid-core fibers which can reach and exceed the performance of the current HERA-B vertex detector, while offering even greater resistance to aging due to radiation effects. This radiation resistance would provide an improved vertex resolution by allowing one to place the detector elements closer to the particle beam, and thus provide an improvement in the measurement of Bs, mixing while extending the accessible region of xs.
DOI: 10.1142/9789812819093_0014
2008
THE CMS MUON SYSTEM AND ITS PERFORMANCE IN THE CMS COSMIC CHALLENGE
DOI: 10.1088/1742-6596/110/12/122004
2008
First measurements of cosmic muons with magnetic field in CMS
The reconstruction of cosmic muons is important for testing and aligning the Compact Muon Solenoid experiment (CMS). In this context the Magnet Test and Cosmic Challenge (MTCC) with its comprehensive cosmic data taking periods including the presence of the 4 Tesla magnetic field has been like a dress rehearsal of detector hardware and software for the upcoming startup of the CMS detector. In addition to data taking also the comparison with simulated events is a crucial part of physics analyses. With respect to these tasks a dedicated cosmic muon generator, CMSCGEN, has been developed and compared with data from MTCC. As an example results from a reconstruction study using the barrel muon system are shown, comparing data and Monte Carlo prediction at the level of single chambers up to reconstructed tracks including momentum measurements.
2007
HERA‐B実験の外側トラッカ検出器 III 動作と性能
DOI: 10.22323/1.314.0702
2018
Enhanced Scope of a Phase-2 CMS Detector for Physics beyond the Standard Model at the High- Luminosity LHC
To extend the LHC physics program, it is foreseen to operate the LHC in the future with an unprecedented high luminosity.To maintain the experiment's physics potential in the harsh environment of this so-called Phase-2, the detector will be upgraded.The silicon tracker and the forward detectors will have to be replaced to cope with radiation damage.At the same time the detector acceptance will be extended and new features such as a L1 track trigger will be implemented.Simulation studies evaluated the performance of the new, proposed detector components and the impact on representative physics channels.In case of searches for new physics, these studies also shape the future research program.The sensitivity to find new physics beyond the standard model (SM) is significantly improved and will allow to extend the reach for heavy vector bosons, for SUSY, dark matter and exotic long-lived signatures, to name a few.
DOI: 10.22323/1.321.0261
2018
Experimental BSM prospects at the HL-LHC
This paper presents examples from the wealth of physics studies to determine the achievable sensitivity at the high-luminosity LHC.Beyond-the-standard-model (BSM) searches concern new heavy bosons, supersymmetric models, exotic signatures with displaced leptons and many more.
DOI: 10.1109/nss/mic42101.2019.9059698
2019
Study of the Effects of Radiation at the CERN Gamma Irradiation Facility on the CMS Drift Tube Muon Detector for HL-LHC
To sustain and extend its discovery potential, the Large Hadron Collider (LHC) will undergo a major upgrade in the coming years, referred to as High Luminosity LHC (HLLHC), aimed to increase its instantaneous luminosity, 5 times larger than the designed limit, and, consequently leading to high levels of radiation, with the goal to collect 10 times larger the original designed integrated luminosity. The drift tube chambers (DT) of CMS muon detector system is built to proficiently measure and trigger on muons in the harsh radiation environment expected during the HL-LHC era. Ageing studies are performed at the CERNs gamma ray irradiation facility (GIF++) by measuring the muon hit efficiency of these detectors at various LHC operation conditions. One such irradiation campaign was started in October 2017, when a spare MB2 chamber moved inside the bunker and irradiated at lower acceleration factors. Two out of twelve layers of the DT chamber were operated while being irradiated with the radioactive source and then their muon hit efficiency was calculated in coincidence with other ten layers which were kept on the standby. The chamber absorbed an integrated dose equivalent to two times the expected integrated luminosity of the HL-LHC. Investigation on the outgassing of cell materials and of the gas components used at the GIF++ are underway and strategies to mitigate the aging effects are also being developed. The effect of radiation on the performance of DT chamber and its impact on the overall muon reconstruction efficiency expected during the HL-LHC are presented.
DOI: 10.22323/1.364.0610
2020
Sensitivity for Heavy Resonances at the HighLuminosity LHC with the Phase-2 CMS Detector
To extend the LHC physics program, it is foreseen to operate the LHC in the future with an unprecedented high luminosity. To maintain the experiment's physics potential in the harsh environment of this so-called phase-2, the detector will be upgraded. At the same time the detector acceptance will be extended and new features such as a L1 track trigger will be implemented. Simulation studies evaluated the physics reach of benchmark searches for physics beyond the SM. One of the open question being discussed right now, are models explaining the observed flavour anomalies. They postulate leptoquarks or Zprime-like new bosons, with enhanced couplings to third generation particles. In this context future searches in the ttbar mass spectrum are discussed, as well as searches for leptoquarks and heavy bosons with tau in the final state. Another class of interesting models suggest compositeness, a fermion substructure, leading to a potential observation of excited leptons or composite neutrinos. All these studies show a significantly enhanced sensitivity and will shape the future research program.
2019
Sensitivity for Heavy Resonances at the HighLuminosity LHC with the Phase-2 CMS Detector
2007
First CMS cosmic data with magnetic field
DOI: 10.1007/978-3-319-47999-6_19-2
2020
Muon Spectrometers
1962
STABILIZATION AND CONTROL SUBSYSTEM
Nimbus satellite - stabilization and control altitude subsystems for yaw, roll and pitch axis
DOI: 10.1140/epjcd/s2004-04-017-7
2004
Early physics reach of CMS
DOI: 10.1109/nssmic.2004.1462244
2005
Potential and challenges of the CMS barrel MUON system
In a hadronic environment, distinct decay kinematics are essential to efficiently trigger on the interesting physics events. The CMS experiment will exploit a system of four muon tracking stations based on 200,000 drift tubes to identify muons and to measure their charge and momentum. The physics requirements are discussed and it is shown how they are fulfilled in terms of design and quality control during production. The chambers are tested with cosmic muons and test beams.
DOI: 10.22323/1.390.0304
2021
Search for excited leptons in CMS
Compositeness models are a popular explanation for the observed three generations of standard model (SM) particles.One consequence of compositeness would be the observation of excited leptons, such as excited electrons, e*, or excited muons, *.At the LHC such particles could be produced in pp collisions under the assumption that leptons are composite objects.Produced excited leptons are expected to transition to their corresponding SM lepton partner via gauge or via contact interaction.CMS has performed a recent search for e* and * in the contact interaction decay channel leading to a two-lepton plus two-jets final state using the 2016 and 2017 sqrt(s) = 13 TeV dataset.While no signal was observed, the exclusion results provide the best limits to date.The poster also compares to other complementary search channels and discusses the greater context of excited leptons searches.
2021
Performance of a Triple-GEM Demonstrator in $pp$ Collisions at the CMS Detector
The Phase-II high luminosity upgrade to the Large Hadron Collider (LHC) is planned for 2023, significantly increasing the collision rate and therefore the background rate, particularly in the high $\eta$ region. To improve both the tracking and triggering of muons, the Compact Muon Solenoid (CMS) Collaboration plans to install triple-layer Gas Electron Multiplier (GEM) detectors in the CMS muon endcaps. Demonstrator GEM detectors were installed in CMS during 2017 to gain operational experience and perform a preliminary investigation of detector performance. We present the results of triple-GEM detector performance studies performed in situ during normal CMS and LHC operations in 2018. The distribution of cluster size and the efficiency to reconstruct high $p_T$ muons in proton--proton collisions are presented as well as the measurement of the environmental background rate to produce hits in the GEM detector.
DOI: 10.1088/1748-0221/16/12/p12026
2021
Benchmarking LHC background particle simulation with the CMS triple-GEM detector
Abstract In 2018, a system of large-size triple-GEM demonstrator chambers was installed in the CMS experiment at CERN's Large Hadron Collider (LHC). The demonstrator's design mimicks that of the final detector, installed for Run-3. A successful Monte Carlo (MC) simulation of the collision-induced background hit rate in this system in proton-proton collisions at 13 TeV is presented. The MC predictions are compared to CMS measurements recorded at an instantaneous luminosity of 1.5 ×10 34 cm -2 s -1 . The simulation framework uses a combination of the FLUKA and GEANT4 packages. FLUKA simulates the radiation environment around the GE1/1 chambers. The particle flux by FLUKA covers energy spectra ranging from 10 -11 to 10 4 MeV for neutrons, 10 -3 to 10 4 MeV for γ's, 10 -2 to 10 4 MeV for e ± , and 10 -1 to 10 4 MeV for charged hadrons. GEANT4 provides an estimate of the detector response (sensitivity) based on an accurate description of the detector geometry, the material composition, and the interaction of particles with the detector layers. The detector hit rate, as obtained from the simulation using FLUKA and GEANT4, is estimated as a function of the perpendicular distance from the beam line and agrees with data within the assigned uncertainties in the range 13.7-14.5%. This simulation framework can be used to obtain a reliable estimate of the background rates expected at the High Luminosity LHC.
DOI: 10.1007/978-3-319-93785-4_19
2021
Muon Spectrometers