ϟ

G. Zilizi

Here are all the papers by G. Zilizi that you can download and read on OA.mg.
G. Zilizi’s last known institution is . Download G. Zilizi PDFs here.

Claim this Profile →
DOI: 10.1016/0168-9002(94)91357-9
1994
Cited 210 times
The L3 silicon microvertex detector
The design and construction of the silicon strip microvertex detector (SMD) of the L3 experiment at LEP are described. We present the sensors, readout electronics, data acquisition system, mechanical assembly and support, displacement monitoring systems and radiation monitoring system of the recently installed double-sided, double-layered SMD. This detector utilizes novel and sophisticated techniques for its readout.
DOI: 10.1016/j.nima.2009.03.252
2009
Cited 7 times
Motions of CMS detector structures due to the magnetic field forces as observed by the Link alignment system during the test of the 4T magnet solenoid
This document describes results obtained from the Link alignment system data recorded during the Compact Muon Solenoid (CMS) Magnet Test. A brief description of the system is followed by a discussion of the detected relative displacements (from micrometres to centimetres) between detector elements and rotations of detector structures (from microradians to milliradians). Observed displacements are studied as functions of the magnetic field intensity. In addition, the reconstructed positions of active element sensors are compared to their positions as measured by photogrammetry and the reconstructed motions due to the magnetic field strength are described.
DOI: 10.1016/0168-9002(94)01226-1
1995
Cited 14 times
The L3 Silicon Microvertex Detector: installation and results on 1993 performance
The status of the Silicon Microvertex Detector (SMD) and its installation into the LEP-I.3experiment are presented, highiighting novel features and sophisticated techniques.Preliminary results based on 1993 data are given and compared with Monte Carlo predictions, to understand the detector performances and its tracking capabilities.
DOI: 10.1016/j.nima.2016.01.002
2016
Motion of CMS detector and mechanical structures during Magnet Cycles and Stability Periods from 2008 to 2013 as observed by the Link Alignment System
Magnet Cycles and Stability Periods of the CMS Experiment are studied with the Alignment Link System data recorded along the 2008–2013 years of operation. The motions of the mechanical structures due to the magnetic field forces are studied and the mechanical stability of the detector during the physics data taking periods is verified.
DOI: 10.1016/j.nima.2012.01.050
2012
CMS structural equilibrium at constant magnetic field as observed by the link alignment system
A study of the time required for the CMS detector to reach structural equilibrium once the magnetic field is ramped to its operational value of 3.8 T is presented. In addition, the results from a stability monitoring at 3.8 T over an eight-month period are given.
DOI: 10.1016/s0168-9002(02)01540-1
2002
Cited 4 times
Design features and test results of the CMS endcap muon chambers
Presented are the main design features and performance results of the Cathode Strip Chambers for the CMS Endcap Muon system. Although the strips are unusually wide (up to 16mm) for the cathode-to-anode wire distance of 5mm, the six-plane structure of these chambers yields a spatial resolution of about 80μm, essentially uniform and independent of the strip width. In addition, the net spatial resolution of about one-tenth of the strip width at the hardware trigger level (300ns) is obtained using a simple network of comparators. Time resolution achieved at the trigger level is ∼4ns (rms) that allows unambiguous tagging of bunch crossings which occur every 25ns. Aging test results, including those obtained with a recirculating gas system, are discussed; only minor aging affects were observed. The aging studies were performed with large-scale chambers; 700m of wire were irradiated for a dose up to 0.4C/cm of the total accumulated charge.
2009
Performance Testing of the CMS Cathode Strip Chambers
The production, installation, and testing of 468 cathode strip chambers for the endcap muon system of the CMS experiment played a critical role in the preparation of the endcap muon system for the final commissioning. Common testing procedures and sets of standard equipment were used at 5 international assembly centers. The chambers were then thoroughly retested after shipment to CERN. Final testing was performed after chamber installation on the steel disks in the CMS detector assembly building. The structure of the detector quality control procedure is presented along with the results of chamber performance validation tests.
DOI: 10.1016/j.nima.2018.04.004
2018
The network of photodetectors and diode lasers of the CMS Link alignment system
The central feature of the CMS Link alignment system is a network of Amorphous Silicon Position Detectors distributed throughout the muon spectrometer that are connected by multiple laser lines. The data collected during the years from 2008 to 2015 is presented confirming an outstanding performance of the photo sensors during more than seven years of operation. Details of the photo sensor readout of the laser signals are presented. The mechanical motions of the CMS detector are monitored using these photosensors and good agreement with distance sensors is obtained.
DOI: 10.1016/j.nima.2020.163639
2020
A survey of the induced currents on the photodetectors used in the CMS Link alignment system
This document presents an overview of the induced photocurrents in the Amorphous Silicon Position Detectors used in the network of diode lasers and photo sensors of the CMS Link alignment system recorded during its eleven years of operation. After a description of the sensors characteristics, the layout of the sensors network is discussed. The sensors are distributed throughout the muon spectrometer and connected by laser lines. The data used correspond to readout information obtained during some of the physics runs from 2008 to 2018.
DOI: 10.1109/nssmic.2002.1239307
2003
CSC Endcap Muon Chambers: design and test results
Presented are the main design features and performance results of the cathode strip chambers (CSCs) for the CMS Endcap Muon System. The six-plane structure of these chambers yields a spatial resolution of about 80 /spl mu/m, essentially uniform and independent of the strip width (up to 16 mm, which is unusually wide for the cathode-to-anode wire distance of 5 mm). In addition, the net spatial resolution of about one-tenth of the strip width at the hardware trigger level (300ns) is obtained using a simple network of comparators. The time resolution achieved at the trigger level is /spl sim/4ns (RMS) that allows unambiguous tagging of bunch crossing occurring every 25 ns. Aging tests, including those obtained with a recirculating gas system, showed only minor aging effects. The aging studies were performed with large-scale chambers; 700 m of wire were irradiated for a dose up to 0.4 C/cm of the total accumulated charge.
DOI: 10.1016/s0920-5632(95)80047-6
1995
1994 running experience with the L3 Silicon Microvertex Detector
The 1994 running experience with the L3 Silicon Microvertex Detector is described; in particular we report on the detector performances observed during the year (namely the DAQ and detection efficiency and the signal to noise ratio) and on the reduction of the noise affecting the detector.
DOI: 10.1007/bf02163881
1991
Determination of Ta impurities in Nb samples by X-rays in neutron activation analysis