ϟ

Diego Matos Figueiredo

Here are all the papers by Diego Matos Figueiredo that you can download and read on OA.mg.
Diego Matos Figueiredo’s last known institution is . Download Diego Matos Figueiredo PDFs here.

Claim this Profile →
DOI: 10.1088/0954-3899/43/11/110201
2016
Cited 108 times
LHC forward physics
The goal of this report is to give a comprehensive overview of the rich field of forward physics, with a special attention to the topics that can be studied at the LHC. The report starts presenting a selection of the Monte Carlo simulation tools currently available, chapter 2, then enters the rich phenomenology of QCD at low, chapter 3, and high, chapter 4, momentum transfer, while the unique scattering conditions of central exclusive production are analyzed in chapter 5. The last two experimental topics, Cosmic Ray and Heavy Ion physics are presented in the chapter 6 and 7 respectively. Chapter 8 is dedicated to the BFKL dynamics, multiparton interactions, and saturation. The report ends with an overview of the forward detectors at LHC. Each chapter is correlated with a comprehensive bibliography, attempting to provide to the interested reader with a wide opportunity for further studies.
DOI: 10.1088/1748-0221/10/01/c01038
2015
Cited 34 times
Test bench development for the radiation Hard GBTX ASIC
This paper presents the development of the GBTX radiation hard ASIC test bench. Developed for the LHC accelerator upgrade programs, the GBTX implements a bidirectional 4.8 Gb/s link between the radiation hard on-detector custom electronics and the off-detector systems. The test bench was used for functional testing of the GBTX and to evaluate its performance in a radiation environment, by conducting Total Ionizing Dose and Single-Event Upsets tests campaigns.
DOI: 10.1088/1748-0221/11/10/t10004
2016
Cited 18 times
Dose rate effects in the radiation damage of the plastic scintillators of the CMS hadron endcap calorimeter
We present measurements of the reduction of light output by plastic scintillators irradiated in the CMS detector during the 8 TeV run of the Large Hadron Collider and show that they indicate a strong dose rate effect. The damage for a given dose is larger for lower dose rate exposures. The results agree with previous measurements of dose rate effects, but are stronger due to the very low dose rates probed. We show that the scaling with dose rate is consistent with that expected from diffusion effects.
DOI: 10.1016/j.jval.2023.09.713
2023
EE447 Working With Probabilistic Models for Cost-Effectiveness Analysis: Computational Tools Integrating Exact Methods vs Simulation-Based Approaches
DOI: 10.1088/1748-0221/13/01/p01002
2018
Brightness and uniformity measurements of plastic scintillator tiles at the CERN H2 test beam
We study the light output, light collection efficiency and signal timing of a variety of organic scintillators that are being considered for the upgrade of the hadronic calorimeter of the CMS detector. The experimental data are collected at the H2 test-beam area at CERN, using a 150 GeV muon beam. In particular, we investigate the usage of over-doped and green-emitting plastic scintillators, two solutions that have not been extensively considered. We present a study of the energy distribution in plastic-scintillator tiles, the hit efficiency as a function of the hit position, and a study of the signal timing for blue and green scintillators.
2020
Test beam results of irradiated single-crystal CVD diamond detectors at DESY-II
DOI: 10.1088/1748-0221/14/08/
2019
Erratum: Dose rate effects in the radiation damage of the plastic scintillators of the CMS hadron endcap calorimeter
DOI: 10.48550/arxiv.1304.7695
2013
Observation of a diffractive contribution to dijet production in proton-proton collisions at $\sqrt{s} = 7$ TeV
The differential cross section measurement for dijet production at proton-proton collisions at $\sqrt{s}=7$ TeV is presented as a function of an approximation for the fractional momentum loss of the scattered proton ($\tildeξ$), an useful observable to distinguish model predictions of diffractive and nondiffractive components. The data was collected by the CMS detector at low instantaneous luminosity runs at LHC, corresponding to an integrated luminosity of $2.7 {\rm nb}^{-1}$. This is the first observation of single diffractive dijets at LHC.
DOI: 10.1088/1748-0221/12/12/p12034
2017
Radioactive source calibration test of the CMS Hadron Endcap Calorimeter test wedge with Phase I upgrade electronics
The Phase I upgrade of the CMS Hadron Endcap Calorimeters consists of new photodetectors (Silicon Photomultipliers in place of Hybrid Photo-Diodes) and front-end electronics. The upgrade will eliminate the noise and the calibration drift of the Hybrid Photo-Diodes and enable the mitigation of the radiation damage of the scintillators and the wavelength shifting fibers with a larger spectral acceptance of the Silicon Photomultipliers. The upgrade also includes increased longitudinal segmentation of the calorimeter readout, which allows pile-up mitigation and recalibration due to depth-dependent radiation damage. As a realistic operational test, the responses of the Hadron Endcap Calorimeter wedges were calibrated with a 60Co radioactive source with upgrade electronics. The test successfully established the procedure for future source calibrations of the Hadron Endcap Calorimeters. Here we describe the instrumentation details and the operational experiences related to the sourcing test.
DOI: 10.1088/1748-0221/14/08/e08001
2019
Erratum: Dose rate effects in the radiation damage of the plastic scintillators of the CMS hadron endcap calorimeter