ϟ

David Mark Raymond

Here are all the papers by David Mark Raymond that you can download and read on OA.mg.
David Mark Raymond’s last known institution is . Download David Mark Raymond PDFs here.

Claim this Profile →
DOI: 10.1088/0031-9155/29/1/005
1984
An electronic instrument for indirectly determining the peak kilovoltage of diagnostic x-ray machines
The instrument described has been developed through several stages over a period of three years; the detector is based on a rare earth fluorescent screen and the complete instrument is relatively simple to construct. The performance of this instrument has been evaluated, and comparison with an independent assessment of a number of the commercial instruments (Rothenberg and Fleischman, Med. Phys., vol.9, p.613, 1982) has shown that this instrument has a measured performance compatible with those commercial instruments tested.
DOI: 10.1002/pen.760010201
1961
Masthead
Polymer Engineering & ScienceVolume 1, Issue 2 p. fmi-fmi MastheadFree Access Masthead First published: April 1961 https://doi.org/10.1002/pen.760010201AboutPDF ToolsRequest permissionExport citationAdd to favoritesTrack citation ShareShare Give accessShare full text accessShare full-text accessPlease review our Terms and Conditions of Use and check box below to share full-text version of article.I have read and accept the Wiley Online Library Terms and Conditions of UseShareable LinkUse the link below to share a full-text version of this article with your friends and colleagues. Learn more.Copy URL Share a linkShare onFacebookTwitterLinked InRedditWechat No abstract is available for this article. Volume1, Issue2April 1961Pages fmi-fmi RelatedInformation
1967
Charge Asymmetry in the Muonic Decay of the K o 2
DOI: 10.2172/4630929
1972
Measurement of the decay K{sub L}{sup 0} yields {pi}{sup 0}{pi}{sup 0}
A measurement of the rate {Gamma}(K{sub L}{sup 0} yields 2{pi}{sup 0} has been made relative to three other rates in a spark chamber scintillation counter experiment. Results are given, which show agreement with the previous average.
DOI: 10.1088/0031-9155/33/3/007
1988
Use of a monolithic dual JFET in a low cost, low noise, charge-sensitive preamplifier for semiconductor radiation detectors (medical application)
A charge-sensitive preamplifier can be simply constructed utilising a 2N5566 monolithic dual JFET with the two FET connected in parallel. The noise performance for this preamplifier is comparable to that for a commercial low noise preamplifier under normal operating conditions. The circuit is unsophisticated, requiring few components, facilitating ease of construction provided attention is paid to the points mentioned. The cost of the components is less than Pounds 20 and can be contrasted to that for commercial devices of several hundred pounds.