ϟ

A. Elliott-Peisert

Here are all the papers by A. Elliott-Peisert that you can download and read on OA.mg.
A. Elliott-Peisert’s last known institution is . Download A. Elliott-Peisert PDFs here.

Claim this Profile →
DOI: 10.1140/epjcd/s2006-02-002-x
2006
Cited 45 times
Reconstruction of the signal amplitude of the CMS electromagnetic calorimeter
The amplitude of the signal collected from the PbWO4 crystals of the CMS electromagnetic calorimeter is reconstructed by a digital filtering technique. The amplitude reconstruction has been studied with test beam data recorded from a fully equipped barrel supermodule. Issues specific to data taken in the test beam are investigated, and the implementation of the method for CMS data taking is discussed.
DOI: 10.1088/1748-0221/9/04/p04007
2014
Cited 25 times
Combined effect of bulk and surface damage on strip insulation properties of proton irradiated n<sup>+</sup>-p silicon strip sensors
Silicon sensors in next generation hadron colliders will face a tremendously harsh radiation environment. Requirement to study rarest reaction channels with statistical constraints has resulted in a huge increment in radiation flux, resulting in both surface damage and bulk damage. For sensors which are used in a charged hadron environment, both of these degrading processes take place simultaneously. Recently it has been observed in proton irradiated n+-p Si strip sensors that n+ strips had a good inter-strip insulation with low values of p-spray and p-stop doping densities which is contrary to the expected behaviour from the current understanding of radiation damage. In this work a simulation model has been devised incorporating radiation damage to understand and provide a possible explanation to the observed behaviour of irradiated sensors.
DOI: 10.1140/epjcd/s2005-02-011-3
2006
Cited 31 times
Results of the first performance tests * of the CMS electromagnetic calorimeter
Performance tests of some aspects of the CMS ECAL were carried out on modules of the "barrel" sub-system in 2002 and 2003. A brief test with high energy electron beams was made in late 2003 to validate prototypes of the new Very Front End electronics. The final versions of the monitoring and cooling systems, and of the high and low voltage regulation were used in these tests. The results are consistent with the performance targets including those for noise and overall energy resolution, required to fulfil the physics programme of CMS at the LHC.
DOI: 10.1088/1748-0221/3/10/p10007
2008
Cited 27 times
Intercalibration of the barrel electromagnetic calorimeter of the CMS experiment at start-up
Calibration of the relative response of the individual channels of the barrel electromagnetic calorimeter of the CMS detector was accomplished, before installation, with cosmic ray muons and test beams. One fourth of the calorimeter was exposed to a beam of high energy electrons and the relative calibration of the channels, the intercalibration, was found to be reproducible to a precision of about 0.3%. Additionally, data were collected with cosmic rays for the entire ECAL barrel during the commissioning phase. By comparing the intercalibration constants obtained with the electron beam data with those from the cosmic ray data, it is demonstrated that the latter provide an intercalibration precision of 1.5% over most of the barrel ECAL. The best intercalibration precision is expected to come from the analysis of events collected in situ during the LHC operation. Using data collected with both electrons and pion beams, several aspects of the intercalibration procedures based on electrons or neutral pions were investigated.
DOI: 10.1088/1748-0221/5/03/p03010
2010
Cited 18 times
Radiation hardness qualification of PbWO<sub>4</sub>scintillation crystals for the CMS Electromagnetic Calorimeter
Ensuring the radiation hardness of PbWO4 crystals was one of the main priorities during the construction of the electromagnetic calorimeter of the CMS experiment at CERN. The production on an industrial scale of radiation hard crystals and their certification over a period of several years represented a difficult challenge both for CMS and for the crystal suppliers. The present article reviews the related scientific and technological problems encountered.
DOI: 10.1016/s0168-9002(00)00182-0
2000
Cited 26 times
New results on silicon microstrip detectors of CMS tracker
Interstrip and backplane capacitances on silicon microstrip detectors with p+ strip on n substrate of 320μm thickness were measured for pitches between 60 and 240μm and width over pitch ratios between 0.13 and 0.5. Parametrisations of capacitance w.r.t. pitch and width were compared with data. The detectors were measured before and after being irradiated to a fluence of 4×1014protons/cm2 of 24GeV/c momentum. The effect of the crystal orientation of the silicon has been found to have a relevant influence on the surface radiation damage, favouring the choice of a 〈100〉 substrate. Working at high bias (up to 500 V in CMS) might be critical for the stability of detector, for a small width over pitch ratio. The influence of having a metal strip larger than the p+ implant has been studied and found to enhance the stability.
DOI: 10.1088/1748-0221/11/04/p04012
2016
Cited 9 times
Beam test evaluation of electromagnetic calorimeter modules made from proton-damaged PbWO4crystals
The performance of electromagnetic calorimeter modules made of proton-irradiated PbWO4 crystals has been studied in beam tests. The modules, similar to those used in the Endcaps of the CMS electromagnetic calorimeter (ECAL), were formed from 5×5 matrices of PbWO4 crystals, which had previously been exposed to 24 GeV protons up to integrated fluences between 2.1× 1013 and 1.3× 1014 cm−2. These correspond to the predicted charged-hadron fluences in the ECAL Endcaps at pseudorapidity η = 2.6 after about 500 fb−1 and 3000 fb−1 respectively, corresponding to the end of the LHC and High Luminosity LHC operation periods. The irradiated crystals have a lower light transmission for wavelengths corresponding to the scintillation light, and a correspondingly reduced light output. A comparison with four crystals irradiated in situ in CMS showed no significant rate dependence of hadron-induced damage. A degradation of the energy resolution and a non-linear response to electron showers are observed in damaged crystals. Direct measurements of the light output from the crystals show the amplitude decreasing and pulse becoming faster as the fluence increases. The latter is interpreted, through comparison with simulation, as a side-effect of the degradation in light transmission. The experimental results obtained can be used to estimate the long term performance of the CMS ECAL.
DOI: 10.1016/s0168-9002(00)00181-9
2000
Cited 7 times
Performance of CMS silicon microstrip detectors with the APV6 readout chip
We present results obtained with full-size wedge silicon microstrip detectors bonded to APV6 (Raymond et al., Proceedings of the 3rd Workshop on Electronics for LHC Experiments, CERN/LHCC/97-60) readout chips. We used two identical modules, each consisting of two crystals bonded together. One module was irradiated with 1.7×1014neutrons/cm2. The detectors have been characterized both in the laboratory and by exposing them to a beam of minimum ionizing particles. The results obtained are a good starting point for the evaluation of the performance of the “ensemble” detector plus readout chip in a version very similar to the final production one. We detected the signal from minimum ionizing particles with a signal-to-noise ratio ranging from 9.3 for the irradiated detector up to 20.5 for the non-irradiated detector, provided the parameters of the readout chips are carefully tuned.
DOI: 10.1016/s0168-9002(99)00419-2
1999
Cited 7 times
The R&amp;D program for silicon detectors in CMS
This paper describes the main achievements in the development of radiation resistant silicon detectors to be used in the CMS tracker. After a general description of the basic requirements for the operation of large semiconductor systems in the LHC environment, the issue of radiation resistance is discussed in detail. Advantages and disadvantages of the different technological options are presented for comparison. Laboratory measurements and test beam data are used to check the performance of several series of prototypes fabricated by different companies. The expected performance of the final detector modules are presented together with preliminary test beam results on system prototypes.
DOI: 10.1016/s0168-9002(98)00081-3
1998
Cited 4 times
Performance of a prototype of the microstrip gas chambers for the CMS experiment at LHC
A set of microstrip gas chamber (MSGC) prototypes, developed for the barrel Tracking Detector of the CMS experiment at LHC, has been tested in a beam. The chambers were 10 cm long, with Pestov or diamond coated glass substrate. The results on the performance of the chambers are reported. The spatial uniformity of the chambers is also illustrated.
DOI: 10.1007/bf03185592
1999
Comparative study of (111) and (100) crystals and capacitance measurements on Si strip detectors in CMS
For the construction of the silicon microstrip detectors for the Tracker of the CMS experiment, two different substrate choices were investigated: A high-resistivity (6 k cm) substrate with (111) crystalorientation and a low-resistivity (2k cm) one with (100) crystalorientation. The interstrip and backplane capacitances were measured before and after the exposure to radiation in a range of strip pitches from 60 μm to 240 μm and for values of the width-over-pitch ratio between 0.1 and 0.5.
DOI: 10.1016/s0168-9002(98)01461-2
1999
The CMS silicon microstrip detectors: research and development
Abstract A large quantity of silicon microstrip detectors is foreseen to be used as part of the CMS tracker. A specific research and development program has been carried out with the aim of defining layouts and technological solutions suitable for the use of silicon detectors in high radiation environment. Results presented here summarise this work on many research areas such as techniques for device manufacturing, pre- and post-irradiation electrical characterization, silicon bulk defects analysis and simulations, system performance analytical calculations and simulations and test beam analysis. As a result of this work we have chosen to use single-sided, AC-coupled, poly silicon biased, 300 μm thick, p + on n substrate detectors. We feel confident that these devices will match the required performances for the CMS tracker provided they can be operated at bias voltages as high as 500 V. Such high-voltage devices have been succesfully manufactured and we are now concentrating our efforts in enhancing yield and reliability.
DOI: 10.1007/bf03185593
1999
High-voltage breakdown studies on Si microstrip detectors
The breakdown performance of CMS barrelmodule prototype detectors and test devices with single and multi-guard structures were studied before and after neutron irradiation up to 2·1014 1 MeV equivalent neutrons. Before irradiation avalanche breakdown occurred at the guard ring implant edges. We measured 100–300 V higher breakdown voltage values for the devices with multi-guard than for devices with single-guard ring. After irradiation and type inversion the breakdown was smoother than before irradiation and the breakdown voltage value increased to 500–600 V for most of the devices.
DOI: 10.1016/s0168-9002(98)01101-2
1999
Test results of heavily irradiated Si detectors
Abstract A large use of silicon microstrip detectors is foreseen for the intermediate part of the CMS tracker. A specific research and development program has been carried out with the aim of finding design layouts and technological solutions for allowing silicon microstrip detectors to be reliably used on a high radiation level environment. As a result of this work single sided, AC-coupled, polysilicon biased, 300 μ m thick, p + on n substrate detectors were chosen. Irradiation tests have been performed on prototypes up to fluence 2×10 14  n/cm 2 . The detector performances do not significantly change if the detectors are biased well above the depletion voltage. S / N is reduced by less than 20%, still enough to insure a good efficiency and space resolution. Multiguard structures has been developed in order to reach high voltage operation (above 500 V).
DOI: 10.1109/23.903854
2000
Test results on heavily irradiated silicon detectors for the CMS experiment at LHC
We report selected results of laboratory measurements and beam tests of heavily irradiated microstrip silicon detectors. The detectors were single-sided devices, produced by different manufacturers and irradiated with different sources, for several total ionizing doses and fluences up to 4 /spl times/10/sup 14/ 1-MeV-equivalent neutrons per cm/sup 2/. Strip resistance and capacitance, detector leakage currents and breakdown performance were measured before and after irradiations. Signal-to-noise ratio and detector efficiency were studied in beam tests, for different values of the detector temperature and of the read-out pitch, as a function of the detector bias voltage. The goal of these test is to optimise the design of the final prototypes for the Silicon Strip Tracker of the CMS experiment at the CERN LHC collider.
DOI: 10.1016/s0920-5632(99)00565-4
1999
R&amp;D for the CMS silicon tracker
DOI: 10.1016/s0168-9002(98)00831-6
1998
The CMS silicon tracker
Abstract The new silicon tracker layout (V4) is presented. The system aspects of the construction are discussed together with the expected tracking performance. Because of the high radiation environment in which the detectors will operate, particular care has been devoted to the study of the characteristics of heavily irradiated detectors. This includes studies on performance (charge collection, cluster size, resolution, efficiency) as a function of the bias voltage, integrated fluence, incidence angle and temperature.
DOI: 10.1016/s0168-9002(97)01247-3
1998
The CMS silicon tracker at LHC
The paper describes the Silicon Tracking System of the Compact Muon Solenoid (CMS) experiment that is foreseen to collect events from p–p collision at the Ecm=14 TeV at the CERN future Large Hadron Collider (LHC). The proposed system consists of four layers of silicon microstrip detectors placed between the two inner layers of the pixel detector and the outer microstrip gas chamber system. The barrel part covers the η region up to 1.8, instrumenting the central radial region between 20 and 50 cm. The forward–backward disks extend the coverage up to η=2.6. This paper will review the main characteristics and performances of the system, the actual status of the R&D activities that we are carrying on, and the status of the milestones we have to fulfill in view of the Technical Design Report expected at the end of the year.